本研究基于141例患者160髋的骨盆正位X线片,提出Area法和Orthogonal法测量全髋关节置换术后髋臼假体前倾角,并与Widmer法和Lewinnek法比较。Area法观察者间与观察者内信度最高(0.992和0.998),耗时更短(27.50秒),与CT三维重建的Pearson相关系数最高(r=0.956),平均差异在1°以内。作者认为Area法最可靠、准确且快速,未支持Orthogonal法优于Widmer或Lewinnek法。

要点

  • Area法观察者间信度0.992、观察者内信度0.998,均为最高。
  • Area法测量耗时27.50秒(标准差3.19),较其他方法更短(p<0.001)。
  • Area法与CT三维重建相关系数r=0.956(p<0.001),平均差异在1°以内。

核心结论

  • 结果支持Area法是最可靠、准确且快速的测量方法。
  • 结果未支持Orthogonal法在统计学上优于Widmer法或Lewinnek法。

研究设计与样本

  • 回顾性研究,分析141例患者160髋初次全髋关节置换术后的骨盆正位X线片。
  • 比较Area法和Orthogonal法与Widmer法、Lewinnek法的信度和准确度。
  • 其中21髋有可用的CT三维重建用于准确度验证。

主要发现

  • 160张骨盆正位片显示Area法与Widmer法及Lewinnek法均有统计学差异(p<0.001和p=0.004)。
  • Area法观察者间信度0.992、观察者内信度0.998,均为最高。
  • Area法完成测量耗时27.50秒(标准差3.19),较其他方法更短(p<0.001)。
  • 21例CT三维重建显示Area法Pearson相关系数最高(r=0.956;p<0.001),与CT的统计学差异最小(p=0.704)。
  • 在放射学前倾角1°至30°范围内,Area法与CT三维重建的平均差异在1°以内。

临床怎么用

  • 原文结论支持Area法作为最可靠、准确且快速的放射学测量方法,但未给出具体临床使用推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty (THA) have been described. These are limited by low reproducibility, are less accurate than CT 3D reconstruction, and are cumbersome to use. These methods also partly rely on the identification of obscured radiological borders of the component. We propose two novel methods, the Area and Orthogonal methods, which have been designed to maximize use of readily identifiable points while maintaining the same trigonometric principles. PATIENTS AND METHODS: A retrospective study of plain radiographs was conducted on 160 hips of 141 patients who had undergone primary THA. We compared the reliability and accuracy of the Area and Orthogonal methods with two of the current leading methods: those of Widmer and Lewinnek, respectively. RESULTS: The 160 anteroposterior pelvis films revealed that the proposed Area method was statistically different from those described by Widmer and Lewinnek (p < 0.001 and p = 0.004, respectively). They gave the highest inter- and intraobserver reliability (0.992 and 0.998, respectively), and took less time (27.50 seconds (sd 3.19); p < 0.001) to complete. In addition, 21 available CT 3D reconstructions revealed the Area method achieved the highest Pearson's correlation coefficient (r = 0.956; p < 0.001) and least statistical difference (p = 0.704) from CT with a mean within 1° of CT-3D reconstruction between ranges of 1° to 30° of measured radiological anteversion. CONCLUSION: Our results support the proposed Area method to be the most reliable, accurate, and speedy. They did not support any statistical superiority of the proposed Orthogonal method to that of the Widmer or Lewinnek method. Cite this article: Bone Joint J 2019;101-B:1042-1049.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Murphy MP, Killen CJ, Ralles SJ, et al. A precise method for determining acetabular component anteversion after total hip arthroplasty. Bone Joint J. 2019. PMID: 31474147. doi:10.1302/0301-620X.101B9.BJJ-2019-0085.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。