外侧半月板移植:固定方式对模拟步态中关节接触力学的影响
研究在6例人尸体膝关节上比较了锁孔式与骨栓式外侧半月板移植固定对模拟步态中关节接触力学的影响。两种骨性固定均较半月板切除改善接触力学,但锁孔式固定恢复接触面积、峰值接触应力及接触中心位置更接近完整膝关节,而骨栓式固定在14%和45%步态周期接触面积显著降低21%至28%,45%步态周期峰值接触应力显著增加34%。
要点
- 锁孔式与骨栓式固定均较半月板切除改善外侧间室接触力学。
- 锁孔式固定在接触面积、峰值应力及接触中心位置上与完整膝无显著差异。
- 骨栓式固定45%步态周期峰值接触应力较完整膝显著增加34%。
核心结论
- 锁孔式与骨栓式固定均较半月板切除改善外侧间室接触力学,但锁孔式固定恢复的接触力学更接近完整膝关节。
研究设计与样本
- 控制性实验室研究,采用6例人尸体膝关节,安装于多方向动态模拟器,测试完整半月板、锁孔式固定、骨栓式固定及半月板切除四种条件。
主要发现
- 骨栓式固定组在模拟步态周期14%和45%时接触面积较完整膝显著降低21%至28%。
- 骨栓式固定组在模拟步态周期45%时峰值接触应力较完整膝显著增加34%,且加权接触中心移位使软骨对软骨接触区受力增加。
- 锁孔式固定组在接触面积、峰值接触应力、半月板足印区与软骨对软骨接触之间的力分布及加权接触中心位置上与完整膝无显著差异。
临床怎么用
- 作者从生物力学角度提倡锁孔式固定,因其能模拟完整膝关节的接触力学;半月板固定方式由外科医生直接掌控。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Controversy exists regarding the optimal bony fixation technique for lateral meniscal allografts. PURPOSE/HYPOTHESIS: The objective was to quantify knee joint contact mechanics across the lateral plateau for keyhole and bone plug meniscal allograft transplant fixation techniques throughout simulated gait. It was hypothesized that both methods of fixation would improve contact mechanics relative to the meniscectomized condition, while keyhole fixation would restore the distribution of contact stress closer to that of the intact knee. STUDY DESIGN: Controlled laboratory study. METHODS: Six human cadaveric knees were mounted on a multidirectional dynamic simulator and subjected to the following conditions: (1) native intact meniscus, (2) keyhole fixation of the native meniscus, (3) bone plug fixation of the native meniscus, and (4) meniscectomy. Contact area, peak contact stress, and the distribution of stress across the tibial plateau were computed at 14% and 45% of the gait cycle, at which axial forces are at their highest. Translation of the weighted center of contact stress throughout simulated gait was computed. RESULTS: Both bony fixation techniques improved contact mechanics relative to the meniscectomized condition. The keyhole technique was not significantly different from the intact condition for the following metrics: contact area, peak contact stress, distribution of force between the meniscal footprint and cartilage-to-cartilage contact, and the position of the weighted center of contact. In contrast, bone plug fixation resulted in a significant decrease of 21% to 28% in contact area at 14% and 45% of the simulated gait cycle, a significant increase in peak contact stresses of 34% at 45% of the gait cycle, and a shift in the weighted center of contact, which increased forces in the cartilage-to-cartilage contact area at 45% of the gait cycle. CONCLUSION: While both keyhole and bone plug fixation methods improved lateral compartment contact mechanics relative to the meniscectomized knee, keyhole fixation restored contact mechanics closer to that of the intact knee. CLINICAL RELEVANCE: Method of meniscal fixation is under the direct control of the surgeon. From a biomechanics perspective, keyhole fixation is advocated for its ability to mimic intact knee joint contact mechanics.
引用
- Brial C, McCarthy M, Adebayo O, et al. Lateral Meniscal Graft Transplantation: Effect of Fixation Method on Joint Contact Mechanics During Simulated Gait. Am J Sports Med. 2019. PMID: 31314996. doi:10.1177/0363546519860113
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。