文献速递关节外科

3D打印全膝关节置换术的放射立体分析评估

Evaluation of a 3D-printed total knee arthroplasty using radiostereometric analysis: assessment of highly porous biological fixation of the tibial baseplate and metal-backed patellar component.
PubMed 文献 · Bone Joint J · 2019-01-01

这项前瞻性队列研究纳入29例初次全膝关节置换术患者,评估高孔隙率3D打印胫骨底板与金属背衬髌骨假体的生物固定效果。患者功能在术后3个月显著改善(p < 0.001),胫骨和髌骨假体迁移主要发生在术后前6周,12至24个月间最大总点运动平均差异分别为0.021 mm和0.089 mm。作者认为生物固定似乎可靠发生,但1例髌骨假体在12至24个月间出现快速迁移,需进一步研究长期稳定性。

要点

  • 术后3个月患者功能显著改善,p < 0.001。
  • 胫骨假体迁移在术后6个月后无变化,髌骨假体迁移在术后6周后无变化。
  • 1例髌骨假体在12至24个月间出现快速迁移。

核心结论

  • 高孔隙率胫骨底板和金属背衬髌骨假体表面似乎可靠地实现生物固定。
  • 1例髌骨假体在12个月后测得快速迁移。
  • 需进一步研究评估3D打印组件的长期稳定性,并确定高迁移组件是否实现固定。

研究设计与样本

  • 前瞻性队列研究,纳入29例接受初次全膝关节置换术的患者。
  • 所有患者均接受高孔隙率胫骨底板和金属背衬髌骨假体。
  • 记录患者报告结局指标,并使用放射立体分析评估植入物迁移。

主要发现

  • 患者功能在术后3个月显著改善(p < 0.001)。
  • 胫骨植入物12至24个月间最大总点运动平均差异为0.021 mm(-0.265至0.572)。
  • 髌骨植入物12至24个月间最大总点运动平均差异为0.089 mm(-0.337至0.758)。
  • 胫骨和髌骨迁移率在术后前6周最大,胫骨平均迁移在6个月后无变化,髌骨平均迁移在6周后无变化。
  • 1例髌骨组件在12至24个月间显示快速迁移率。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 需进一步研究评估3D打印组件的长期稳定性,并确定高迁移组件是否实现固定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Our intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone. PATIENTS AND METHODS: A total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis. RESULTS: Patient function significantly improved by three months postoperatively (p < 0.001). Mean difference in maximum total point motion between 12 and 24 months was 0.021 mm (-0.265 to 0.572) for the tibial implant and 0.089 mm (-0.337 to 0.758) for the patellar implant. The rate of tibial and patellar migration was largest over the first six postoperative weeks, with no changes in mean tibia migration occurring after six months, and no changes in mean patellar migration occurring after six weeks. One patellar component showed a rapid rate of migration between 12 and 24 months. CONCLUSION: Biological fixation appears to occur reliably on the highly porous implant surface of the tibial baseplate and metal-backed patellar component. Rapid migration after 12 months was measured for one patellar component. Further investigation is required to assess the long-term stability of the 3D-printed components and to determine if the high-migrating components achieve fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):40-47.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Sporer S, MacLean L, Burger A, et al. Evaluation of a 3D-printed total knee arthroplasty using radiostereometric analysis: assessment of highly porous biological fixation of the tibial baseplate and metal-backed patellar component. Bone Joint J. 2019. PMID: 31256643. doi:10.1302/0301-620X.101B7.BJJ-2018-1466.R1