维生素E弥散高交联聚乙烯磨损与多孔钛涂层髋臼杯稳定性的七年随机对照试验

Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis.
PubMed 文献 · Bone Joint J · 2019-01-01

89例全髋关节置换患者随机接受维生素E弥散高交联聚乙烯内衬(44例)或中度交联聚乙烯内衬(45例),均使用多孔钛涂层髋臼杯。七年随访73例(82%),两组的线性近端穿透、患者报告结局和放射透亮线发生率无显著差异;放射透亮线患者(34%)的髋臼杯迁移更大且患者报告结局更低。

要点

  • 七年线性近端穿透VEPE组为-0.07 mm,ModXLPE组为0.00 mm,差异无统计学意义(p=0.116)。
  • 髋臼杯平均近端迁移率为每年0.04 mm,无因无菌性松动翻修的植入物。
  • 放射透亮线患者(34%)的髋臼杯迁移更大(平均差0.6 mm,p<0.001),患者报告结局更低。

核心结论

  • 这是首个报告维生素E弥散高交联聚乙烯七年放射立体分析结果的随机对照试验。
  • 所有磨损率均低于既往报告的骨溶解阈值(每年0.1 mm)。
  • 多孔钛涂层髋臼杯七年内表现出可接受的初始稳定性,表现为低迁移和无菌性松动。
  • 髋臼放射透亮线与更大的髋臼杯迁移和更低的患者报告结局评分相关。

研究设计与样本

  • 前瞻性随机对照试验,共纳入89例患者,均接受多孔钛涂层髋臼杯。
  • 患者随机接受维生素E弥散高交联聚乙烯内衬(44例)或中度交联聚乙烯内衬(45例)。
  • 使用放射立体分析测量聚乙烯磨损和组件迁移,并校正体重指数、活动水平、髋臼外倾角、前倾角和股骨头尺寸。
  • 随访时评估平片放射透亮线并施测患者报告结局量表。
  • 73例患者(82%)完成七年随访。

主要发现

  • 七年平均线性近端穿透:VEPE组-0.07 mm(标准差0.16) vs ModXLPE组0.00 mm(标准差0.22),p=0.116。
  • 患者报告结局评分两组间无差异(p=0.310至0.807)。
  • 放射透亮线发生率两组间无差异(p=0.330)。
  • 髋臼杯平均近端迁移率为每年0.04 mm(标准差0.09)。
  • 七年时放射透亮线患者(34%)迁移更大(平均差0.6 mm,标准差0.2;p<0.001),且患者报告结局评分更低(p=0.009至p=0.045)。

关键数值与推荐

  • 所有磨损率均低于既往报告的骨溶解阈值(每年0.1 mm)。
  • 多孔钛涂层髋臼杯七年内表现出可接受的初始稳定性,表现为低迁移和无菌性松动。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. PATIENTS AND METHODS: A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. RESULTS: In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (sd 0.16) and 0.00 mm (sd 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (sd 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (sd 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. CONCLUSION: This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760-767.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Galea VP, Rojanasopondist P, Laursen M, et al. Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis. Bone Joint J. 2019. PMID: 31256674. doi:10.1302/0301-620X.101B7.BJJ-2019-0268.R1