双侧高髋中心技术提供与解剖重建相似的步态参数:双侧发育性髋关节发育不良全髋置换步态分析
研究纳入20例双侧Crowe III-IV型发育性髋关节发育不良并完成双侧全髋置换、随访至少2年的患者(40髋),比较解剖重建组(10例20髋)与高髋中心重建组(10例20髋)的步态特征。结果显示两组步态参数无显著差异,动态髋关节后伸峰值在高髋中心组为-9.71°±7.46°、解剖重建组为-6.80°±11.44°,差异无统计学意义(P=0.09)。作者认为双侧高髋中心技术可提供与解剖重建相似的步态特征,在特别困难的病例中可根据术者决定优先选择。
要点
- 双侧高髋中心组与解剖重建组步态时空、运动学和动力学参数均值相似,无显著差异。
- 动态髋关节后伸峰值高髋中心组-9.71°±7.46°低于解剖重建组-6.80°±11.44°,但差异无统计学意义(P=0.09)。
- 作者认为双侧高髋中心技术可提供与解剖重建相似的步态特征,在特别困难病例中可根据术者决定优先选择。
核心结论
- 双侧高髋中心技术可提供与解剖重建相似的步态特征,在特别困难的病例中可根据术者决定优先选择。
研究设计与样本
- 纳入20例双侧Crowe III-IV型发育性髋关节发育不良行双侧全髋置换且随访至少2年的患者(40髋),解剖重建组10例20髋、高髋中心组10例20髋,通过体表标记、周围相机和步行平台力台进行步态分析。
主要发现
- 两组步态参数无显著差异,时空、运动学和动力学均值相似。
- 动态髋关节后伸峰值高髋中心组为-9.71°±7.46°,解剖重建组为-6.80°±11.44°,高髋中心组较低但差异无统计学意义(P=0.09)。
临床怎么用
- 作者认为双侧高髋中心技术可提供与解剖重建相似的步态特征,在特别困难的病例中可根据术者决定优先选择。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total hip arthroplasty in severe dysplasia is challenging due to diminished periacetabular bone stock and the highly placed femoral head. Although anatomical reconstruction of the hip, with required interventions such as subtrochanteric osteotomy and graft usage, is the main aim of the procedure, good long-term clinical outcomes of the high hip center technique have also been reported. Information regarding the effect of hip center placement on gait characteristics is limited; therefore, the aim of this study is to analyze the differences in gait parameters between the high hip center technique and anatomical reconstruction of the hip. METHODS: Twenty patients (40 hips) with bilateral Crowe type III-IV developmental dysplasia of the hip who underwent bilateral total hip arthroplasty and completed at least 2 years of follow-up were included. Group 1 comprised 10 patients (20 hips) who underwent anatomical hip center reconstruction, while group 2 comprised 10 patients (20 hips) who underwent high hip center reconstruction. The gait characteristics of patients were examined through markers placed in certain anatomical regions, the cameras placed around, and the force plates embedded in the walking platform. RESULTS: There was no significant difference in the gait characteristics according to the location of the hip rotation center. The mean temporospatial, kinematic, and kinetic values were similar between the groups. The most prominent difference was in the peak dynamic hip extension, which was lower in group 2 (-9.71° ± 7.46°) compared to group 1 (-6.80° ± 11.44°), although it was not statistically significant (P = .09). CONCLUSION: The bilateral high hip center technique can provide similar gait characteristics as anatomical reconstruction and may be preferred in particularly difficult cases based on the surgeon's decision.
引用
- Karaismailoglu B, Kaynak G, Can A, et al. Bilateral High Hip Center Provides Gait Parameters Similar to Anatomical Reconstruction: A Gait Analysis Study in Hip Replacement Patients With Bilateral Developmental Dysplasia. J Arthroplasty. 2019. PMID: 31353253. doi:10.1016/j.arth.2019.06.063
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。