文献速递关节外科创伤骨科

载抗生素多孔钽可作为抗菌药物递送载体

Antibiotic-loaded tantalum may serve as an antimicrobial delivery agent.
PubMed 文献 · Bone Joint J · 2019-01-01

该体外研究比较载万古霉素多孔钽柱与载抗生素骨水泥对甲氧西林敏感金黄色葡萄球菌(MSSA)的抑菌时长和抑菌圈直径,并评估多孔钽自身的抗菌特性。结果显示多孔钽柱抑菌12天、骨水泥柱9天;第1天抑菌圈直径多孔钽组28.6 mm vs 骨水泥组19.8 mm(p < 0.001),第10天多孔钽组3.8 mm vs 骨水泥组0 mm(p < 0.001);仅浸泡磷酸盐缓冲液的多孔钽柱无抑菌圈。作者认为多孔钽较骨水泥释放抗生素更持久,并建议进一步研究载抗生素多孔钽植入物在翻修关节置换术中的应用优势。

要点

  • 多孔钽柱对MSSA的抑菌时长为12天,骨水泥柱为9天。
  • 第1天抑菌圈直径多孔钽组28.6 mm vs 骨水泥组19.8 mm(p < 0.001)。
  • 仅浸泡磷酸盐缓冲液的多孔钽柱未显示抑菌圈。

核心结论

  • 与骨水泥相比,多孔钽释放抗生素的时间更长。
  • 作者建议进一步研究载抗生素多孔钽植入物在翻修关节置换术中的应用优势。

研究设计与样本

  • 体外研究,使用10个多孔钽柱和10个骨水泥柱,多孔钽柱浸渍万古霉素,骨水泥柱制备时也加入万古霉素。
  • 将柱体置于接种MSSA的琼脂平板上,每日测量抑菌圈直径并将柱体转移至新接种平板,用游标卡尺和自动计算机评估测量抑菌圈,并评估观察者内和观察者间可重复性。
  • 两组间平均抑菌圈比较采用Wilcoxon检验。

主要发现

  • MSSA被多孔钽柱抑制12天,被骨水泥柱抑制9天。
  • 第1天平均抑菌圈直径多孔钽组28.6 mm vs 骨水泥组19.8 mm(p < 0.001)。
  • 第10天平均抑菌圈直径多孔钽组3.8 mm vs 骨水泥组0 mm(p < 0.001)。
  • 仅浸泡磷酸盐缓冲液的多孔钽柱未显示抑菌圈。

局限性

  • 作者在结论中提出需进一步研究评估载抗生素多孔钽植入物在翻修关节置换术中的应用优势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aims of this study were to compare the mean duration of antibiotic release and the mean zone of inhibition between vancomycin-loaded porous tantalum cylinders and antibiotic-loaded bone cement at intervals, and to evaluate potential intrinsic antimicrobial properties of tantalum in an in vitro medium environment against methicillin-sensitive Staphylococcus aureus (MSSA). MATERIALS AND METHODS: Ten porous tantalum cylinders and ten cylinders of cement were used. The tantalum cylinders were impregnated with vancomycin, which was also added during preparation of the cylinders of cement. The cylinders were then placed on agar plates inoculated with MSSA. The diameter of the inhibition zone was measured each day, and the cylinders were transferred to a new inoculated plate. Inhibition zones were measured with a Vernier caliper and using an automated computed evaluation, and the intra- and interobserver reproducibility were measured. The mean inhibition zones between the two groups were compared with Wilcoxon's test. RESULTS: MSSA was inhibited for 12 days by the tantalum cylinders and for nine days by the cement cylinders. At day one, the mean zone of inhibition was 28.6 mm for the tantalum and 19.8 mm for the cement group (p < 0.001). At day ten, the mean zone of inhibition was 3.8 mm for the tantalum and 0 mm for the cement group (p < 0.001). The porous tantalum cylinders soaked only with phosphate buffered solution showed no zone of inhibition. CONCLUSION: Compared with cement, tantalum could release antibiotics for longer. Further studies should assess the advantages of using antibiotic-loaded porous tantalum implants at revision arthroplasty. Cite this article: Bone Joint J 2019;101-B:848-851.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Sautet P, Parratte S, Mékidèche T, et al. Antibiotic-loaded tantalum may serve as an antimicrobial delivery agent. Bone Joint J. 2019. PMID: 31256673. doi:10.1302/0301-620X.101B7.BJJ-2018-1206.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。