全髋关节置换术中基于计算机断层扫描的导航系统在Crowe IV型与Crowe I型发育不良中的准确性相当:一项病例对照研究
该病例对照研究纳入Crowe IV型组29例患者34髋与Crowe I型组32例患者34髋,比较基于CT的导航系统在初次全髋关节置换术中髋臼假体定位的准确性。结果显示,两组髋臼杯尺寸准确率分别为79.4%和94.1%,差异无统计学意义(P=0.075),髋臼杯角度和三维位置的平均偏差在两组间相当。作者认为,使用基于CT的导航系统可对Crowe IV型患者精确植入髋臼假体,其准确性与Crowe I型相当。
要点
- Crowe IV型组与Crowe I型组各34髋,按年龄、性别、体质指数和手术入路匹配。
- 髋臼杯尺寸准确率在Crowe IV型组为79.4%,在Crowe I型组为94.1%,差异无统计学意义(P=0.075)。
- 两组髋臼杯角度和三维位置的平均偏差相当。
核心结论
- 使用基于CT的导航系统可对Crowe IV型患者精确植入髋臼假体,其准确性与Crowe I型相当。
- 基于CT的导航系统是一种有用的术中工具,可精确植入髋臼假体,尤其适用于Crowe IV型等严重骨盆畸形。
研究设计与样本
- 病例对照研究,纳入2006年至2018年期间接受初次全髋关节置换术的患者。
- Crowe IV型组:29例患者共34髋;Crowe I型组:32例患者共34髋,按年龄、性别、体质指数和手术入路与Crowe IV型组匹配。
- 评估指标包括术前计划与最终植入的髋臼杯尺寸准确性,以及术前计划与术后记录的髋臼杯角度和髋臼假体三维位置的平均偏差。
主要发现
- 髋臼杯尺寸准确率在Crowe IV型组为79.4%,在Crowe I型组为94.1%,差异无统计学意义(P=0.075)。
- 髋臼杯角度和三维位置的平均偏差在两组间相当。
临床怎么用
- 作者认为,基于CT的导航系统是一种有用的术中工具,可精确植入髋臼假体,尤其适用于Crowe IV型等严重骨盆畸形。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Clinical outcomes of total hip arthroplasty (THA) for Crowe type IV are poorer than for Crowe type I, because it is more difficult to accurately position the acetabular components. This study aimed to examine the accuracy of the computed tomography (CT)-based navigation system for acetabular component positioning in primary THA for Crowe type IV. METHODS: From 2006 to 2018, 29 patients who underwent 34 primary THAs for Crowe type IV were enrolled in the "Type IV" group and 32 patients who underwent 34 THAs for Crowe type I were enrolled in the "Type I" group, formed by matching patients in the Type IV group on age, gender, body mass index, and surgical approach. We investigated (1) the accuracy of the cup size between that at preoperative planning and that actually implanted and (2) the mean deviation of the cup angle and 3-dimensional position of acetabular components between preoperative plan and postoperative records. RESULTS: The accuracy of the cup size was 79.4% and 94.1% in the Type IV and Type I groups, respectively, without a statistically significant change detected (P = .075). The mean deviations of the cup angle and 3-dimensional position were comparable in both groups. CONCLUSION: Using the CT-based navigation system, it was possible to accurately implant the acetabular component for Crowe type IV, and the accuracy was comparable to that for Crowe type I. The CT-based navigation system is a useful intraoperative tool to accurately implant the acetabular component, especially with severe pelvic deformities such as Crowe type IV.