铰链膝联合钽锥行无菌性翻修全膝关节置换术的最低10年随访临床生存率

Clinical Survivorship of Aseptic Revision Total Knee Arthroplasty Using Hinged Knees and Tantalum Cones at Minimum 10-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2019-07-02

回顾性分析单中心2007至2009年38例无菌性翻修全膝关节置换术患者,排除死亡及失访后纳入25例患者共32个钽锥,最低随访10年(平均126.5个月)。24/32个钽锥(75%)未行任何更换而存活,无菌性松动翻修5/32(15.6%)、假体周围感染翻修3/32(9.4%),存活者平均功能性膝关节协会评分69.6分。作者认为多孔钽锥长期耐久性尚可但不算理想,建议尽可能使用旋转铰链设计以降低无菌性松动风险。

要点

  • 最低随访10年时24/32个钽锥(75%)未更换而存活。
  • 无菌性松动翻修5/32(15.6%),假体周围感染翻修3/32(9.4%)。
  • 5例无菌性松动翻修中4例使用的是单纯铰链膝。

核心结论

  • 翻修全膝关节置换术中多孔钽锥的长期耐久性未达理想但尚属合理。
  • 作者建议尽可能使用旋转铰链设计以降低无菌性松动风险。
  • 作者认为进一步与其他技术或假体进行长期对比分析有助于明确最佳治疗方法。

研究设计与样本

  • 回顾性研究,初始队列为2007至2009年在单家机构接受无菌性翻修全膝关节置换术的38例患者。
  • 排除死亡及失访患者后,纳入25例患者、共植入32个钽锥,最低随访10年(平均126.5个月,范围120-142,标准差5.92)。

主要发现

  • 最低10年后,18例患者中24/32个钽锥(75%)未行任何更换而存活。
  • 钽锥翻修原因包括无菌性松动(5/32个钽锥;15.6%)和假体周围感染(3/32个钽锥;9.4%)。
  • 5例因无菌性松动翻修中4例植入的是单纯铰链膝。
  • 存活者平均功能性膝关节协会评分为69.6分(范围10-100,标准差30.85),膝关节平均屈曲度为92°(范围30°-120°,标准差22.09)。

临床怎么用

  • 作者建议在翻修全膝关节置换术中尽可能使用旋转铰链设计以降低无菌性松动风险。
  • 作者认为进一步与其他技术或假体进行长期对比分析可帮助明确最佳治疗方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The reconstruction of severe bone loss utilizing porous tantalum cones in patients undergoing revision total knee arthroplasty (TKA) has been established in the last years. However, reports on a long-term follow-up to assess the durability of such implants when combined with hinged knee designs are lacking. The current study aimed to evaluate the results of a previous study cohort at a minimum follow-up of 10 years. METHODS: A retrospective review was performed. The initial study cohort comprised of 38 patients who underwent aseptic revision TKA between 2007 and 2009 at a single institution. After exclusion of the deceased patients and patients who were lost to follow-up, 25 patients with hinged knees and 32 cones implanted were included with a minimum follow-up of 10 years (mean = 126.5 months, range 120-142, standard deviation [SD] = 5.92). Survivorship was determined, and re-revisions were observed. Functional Knee Society Score was assessed. RESULTS: After a minimum of 10 years, 24 of 32 cones (75%) had survived without any exchange in 18 patients. Reasons for cone revision included aseptic loosening (5/32 cones; 15.6%) and periprosthetic joint infection (3/32 cones; 9.4%). In 4 of the five revisions due to aseptic loosening, pure hinged knees had been implanted. The mean functional Knee Society Score of the survivors was 69.6 points (range 10-100, SD = 30.85), and the average flexion ability of the knee was 92° (range 30°-120°, SD = 22.09). CONCLUSION: Porous tantalum cones in revision TKA exhibited no favorable but reasonable long-term durability. Rotating-hinge designs should be used whenever possible to reduce the risk of aseptic loosening. Further comparative long-term analyses with other techniques or implants could inform us about the best treatment method.