文献速递关节外科

全膝关节翻修术中单纯更换聚乙烯衬垫的十年生存率优异

Isolated revision of the polyethylene component at revision total knee arthroplasty has excellent survivorship at ten years.
PubMed 文献 · Bone Joint J · 2019-01-01

本研究纳入64例非感染、假体稳定且股骨或胫骨假体固定良好的全膝关节置换术后患者,在1998至2006年间行单纯胫骨聚乙烯衬垫更换的翻修术,平均随访13.2年(10.0至19.1)。末次随访时51例存活患者中仅7例需再手术,膝关节协会评分从翻修前平均78.4改善至末次随访平均91.6。作者认为在假体对线满意、固定良好且软组织可平衡的情况下,单纯聚乙烯更换可提供持久解决方案。

要点

  • 单纯聚乙烯衬垫更换翻修术后平均随访13.2年,51例存活患者中仅7例需再手术。
  • 膝关节协会评分从翻修前平均78.4提升至末次随访平均91.6。
  • 作者认为在假体对线满意、固定良好且软组织可平衡时,单纯聚乙烯更换可提供持久解决方案。

核心结论

  • 在股骨和胫骨假体对线满意且固定良好、软组织可平衡的适当情况下,单纯聚乙烯更换可为翻修全膝关节置换患者提供持久解决方案。

研究设计与样本

  • 回顾性队列研究,纳入1998至2006年八年间64例非感染、假体稳定且接受单纯聚乙烯衬垫更换的翻修全膝关节置换患者,平均随访13.2年(10.0至19.1)。

主要发现

  • 翻修时患者平均年龄72.2岁(48至88),女性36例(56%)、男性28例(44%),从初次全膝关节置换到翻修的平均时间为9.1年(2.2至16.1)。
  • 末次随访时13例患者死亡,51例存活患者中仅7例需再手术。
  • 翻修前膝关节协会评分平均78.4(24至100),翻修后六周平均总评分93.5(38至100),末次随访平均91.6(36至100)。

临床怎么用

  • 作者认为,在股骨和胫骨假体对线满意且固定良好、软组织可平衡的适当情况下,单纯聚乙烯更换可为翻修全膝关节置换患者提供持久解决方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to establish the results of isolated exchange of the tibial polyethylene insert in revision total knee arthroplasty (RTKA) in patients with well-fixed femoral or tibial components. We report on a series of RTKAs where only the polyethylene was replaced, and the patients were followed for a mean of 13.2 years (10.0 to 19.1). PATIENTS AND METHODS: Our study group consisted of 64 non-infected, grossly stable TKA patients revised over an eight-year period (1998 to 2006). The mean age of the patients at time of revision was 72.2 years (48 to 88). There were 36 females (56%) and 28 males (44%) in the cohort. All patients had received the same cemented, cruciate-retaining patella resurfaced primary TKA. All subsequently underwent an isolated polyethylene insert exchange. The mean time from the primary TKA to RTKA was 9.1 years (2.2 to 16.1). RESULTS: At final follow-up, 13 patients had died, leaving 51 patients for study. Only seven of these patients had required re-operation. Knee Society scores (KSS) prior to RTKA were a mean of 78.4 (24 to 100). By six weeks post-revision, the mean total KSS was 93.5 (38 to 100) and at final follow-up, they had a mean of 91.6 (36 to 100). CONCLUSION: In appropriate circumstances, where the femoral and tibial components are satisfactorily aligned and well fixed, and where the soft tissues can be balanced, a polyethylene exchange alone can provide a durable solution for these RTKA patients. Cite this article: Bone Joint J 2019;101-B(7 Supple C):104-107.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Greenwell PH, Shield WP, Chapman DM, et al. Isolated revision of the polyethylene component at revision total knee arthroplasty has excellent survivorship at ten years. Bone Joint J. 2019. PMID: 31256651. doi:10.1302/0301-620X.101B7.BJJ-2018-1498.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。