全膝关节翻修术中单纯更换聚乙烯衬垫的十年生存率优异
本研究纳入64例非感染、假体稳定且股骨或胫骨假体固定良好的全膝关节置换术后患者,在1998至2006年间行单纯胫骨聚乙烯衬垫更换的翻修术,平均随访13.2年(10.0至19.1)。末次随访时51例存活患者中仅7例需再手术,膝关节协会评分从翻修前平均78.4改善至末次随访平均91.6。作者认为在假体对线满意、固定良好且软组织可平衡的情况下,单纯聚乙烯更换可提供持久解决方案。
要点
- 单纯聚乙烯衬垫更换翻修术后平均随访13.2年,51例存活患者中仅7例需再手术。
- 膝关节协会评分从翻修前平均78.4提升至末次随访平均91.6。
- 作者认为在假体对线满意、固定良好且软组织可平衡时,单纯聚乙烯更换可提供持久解决方案。
核心结论
- 在股骨和胫骨假体对线满意且固定良好、软组织可平衡的适当情况下,单纯聚乙烯更换可为翻修全膝关节置换患者提供持久解决方案。
研究设计与样本
- 回顾性队列研究,纳入1998至2006年八年间64例非感染、假体稳定且接受单纯聚乙烯衬垫更换的翻修全膝关节置换患者,平均随访13.2年(10.0至19.1)。
主要发现
- 翻修时患者平均年龄72.2岁(48至88),女性36例(56%)、男性28例(44%),从初次全膝关节置换到翻修的平均时间为9.1年(2.2至16.1)。
- 末次随访时13例患者死亡,51例存活患者中仅7例需再手术。
- 翻修前膝关节协会评分平均78.4(24至100),翻修后六周平均总评分93.5(38至100),末次随访平均91.6(36至100)。
临床怎么用
- 作者认为,在股骨和胫骨假体对线满意且固定良好、软组织可平衡的适当情况下,单纯聚乙烯更换可为翻修全膝关节置换患者提供持久解决方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this study was to establish the results of isolated exchange of the tibial polyethylene insert in revision total knee arthroplasty (RTKA) in patients with well-fixed femoral or tibial components. We report on a series of RTKAs where only the polyethylene was replaced, and the patients were followed for a mean of 13.2 years (10.0 to 19.1). PATIENTS AND METHODS: Our study group consisted of 64 non-infected, grossly stable TKA patients revised over an eight-year period (1998 to 2006). The mean age of the patients at time of revision was 72.2 years (48 to 88). There were 36 females (56%) and 28 males (44%) in the cohort. All patients had received the same cemented, cruciate-retaining patella resurfaced primary TKA. All subsequently underwent an isolated polyethylene insert exchange. The mean time from the primary TKA to RTKA was 9.1 years (2.2 to 16.1). RESULTS: At final follow-up, 13 patients had died, leaving 51 patients for study. Only seven of these patients had required re-operation. Knee Society scores (KSS) prior to RTKA were a mean of 78.4 (24 to 100). By six weeks post-revision, the mean total KSS was 93.5 (38 to 100) and at final follow-up, they had a mean of 91.6 (36 to 100). CONCLUSION: In appropriate circumstances, where the femoral and tibial components are satisfactorily aligned and well fixed, and where the soft tissues can be balanced, a polyethylene exchange alone can provide a durable solution for these RTKA patients. Cite this article: Bone Joint J 2019;101-B(7 Supple C):104-107.
引用
- Greenwell PH, Shield WP, Chapman DM, et al. Isolated revision of the polyethylene component at revision total knee arthroplasty has excellent survivorship at ten years. Bone Joint J. 2019. PMID: 31256651. doi:10.1302/0301-620X.101B7.BJJ-2018-1498.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。