文献速递关节外科

短期迁移在判断骨水泥型与无骨水泥型全膝关节置换术长期稳定固定中的预测价值

Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties.
PubMed 文献 · Bone Joint J · 2019-01-01

本研究纳入79例(54例女性)至少术后10年(平均12年,范围10至14年)的全膝关节置换患者,其中58例骨水泥型、21例无骨水泥型胫骨组件,比较1年、2年与长期迁移并评估预测能力。1年和2年迁移与长期迁移显著相关(p < 0.001)。骨水泥组长期迁移中位数0.6 mm(最大总点运动,四分位距0.4至0.9),无骨水泥组0.6 mm(四分位距0.3至1.1),两组无差异(p = 0.99);无骨水泥组件诱导位移显著更低(p < 0.001)。结论支持短期迁移对长期固定的预测价值。

要点

  • 1年和2年迁移与长期迁移显著相关(p < 0.001)。
  • 骨水泥组与无骨水泥组长期迁移中位数均为0.6 mm,无差异(p = 0.99)。
  • 无骨水泥组件长期随访时诱导位移显著更低(p < 0.001)。

核心结论

  • 长期迁移与2年迁移强相关,支持短期迁移对长期固定的预测价值。
  • 骨水泥型与无骨水泥型胫骨组件长期迁移无差异,但无骨水泥组件长期随访时诱导位移显著更低,提示固定更优。

研究设计与样本

  • 招募曾参与2年随访放射立体照相测量分析(RSA)迁移研究的患者,返回进行至少术后10年的长期随访。
  • 研究两种制造商的两种骨水泥型胫骨设计与一种多孔金属单块无骨水泥型胫骨设计。
  • 长期随访时行仰卧位RSA检查测定迁移,并行负重(单腿站立)检查测定诱导位移。
  • 共79例患者(54例女性)返回,平均术后时间12年(10至14年);骨水泥型胫骨组件58例,无骨水泥型21例。

主要发现

  • 1年与2年迁移均与长期迁移显著相关(p < 0.001)。
  • 长期随访时迁移中位数:骨水泥组0.6 mm(最大总点运动,四分位距0.4至0.9),无骨水泥组0.6 mm(四分位距0.3至1.1),两组无差异(p = 0.99)。
  • 无骨水泥组件的诱导位移显著低于骨水泥组件(p < 0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Early implant migration measured with radiostereometric analysis (RSA) has been proposed as a useful predictor of long-term fixation of tibial components in total knee arthroplasty. Evaluation of actual long-term fixation is of interest for cemented components, as well as for cementless fixation, which may offer long-term advantages once osseointegration has occurred. The objective of this study was to compare the long-term migration with one- and two-year migration to evaluate the predictive ability of short-term migration data and to compare migration and inducible displacement between cemented and cementless (porous metal monoblock) components at least ten years postoperatively. PATIENTS AND METHODS: Patients who had participated in RSA migration studies with two-year follow-up were recruited to return for a long-term follow-up, at least ten years from surgery. Two cemented tibial designs from two manufacturers and one porous metal monoblock cementless tibial design were studied. At the long-term follow-up, patients had supine RSA examinations to determine migration and loaded examinations (single leg stance) to determine inducible displacement. In total, 79 patients (54 female) returned, with mean time since surgery of 12 years (10 to 14). There were 58 cemented and 21 cementless tibial components. RESULTS: Migration at one year and two years was significantly correlated with long-term migration (p < 0.001). Median migration at the long-term follow-up was 0.6 mm (maximum total point motion; interquartile range (IQR) 0.4 to 0.9) for the cemented group and 0.6 mm (IQR 0.3 to 1.1) for the cementless group with no difference between groups (p = 0.99). Inducible displacement was significantly lower for the cementless components (p < 0.001). CONCLUSION: Long-term migration was strongly correlated with two-year migration. Although long-term migration was not different for cemented or cementless tibial components, inducible displacement at the long-term visit was significantly lower for these cementless components, suggesting superior fixation. These findings support the predictive value of short-term migration in determining long-term fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):55-60.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Laende EK, Richardson CG, Dunbar MJ, et al. Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties. Bone Joint J. 2019. PMID: 31256645. doi:10.1302/0301-620X.101B7.BJJ-2018-1493.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。