恶性骨肿瘤股骨近端置换中双极半髋关节置换术后髋臼磨损
该回顾性研究纳入112例恶性骨肿瘤切除后行股骨近端置换且影像随访超过12个月的患者,髋臼磨损患病率为28.6%,5例(4.6%)需二次转为全髋关节置换,年龄小于40岁(P=0.035)和随访时间更长(63 vs 43个月,P=0.004)是髋臼磨损的显著危险因素,脱位率为0.9%。
要点
- 髋臼磨损患病率28.6%,二次转为全髋关节置换者占4.6%。
- 年龄小于40岁(P=0.035)和随访时间更长(63 vs 43个月,P=0.004)是髋臼磨损的显著危险因素。
- 脱位率0.9%,髋关节不稳定性罕见。
核心结论
- 双极半髋关节置换股骨近端置换是肿瘤切除后耐久的重建方式。
- 髋关节不稳定性罕见。
- 髋臼侵蚀罕见,且可通过转为全髋关节置换成功治疗。
- 年轻且长期生存超过10年的患者存在风险。
- 在转移瘤重建中,不稳定性和髋臼磨损罕见。
研究设计与样本
- 回顾性识别112例恶性骨肿瘤切除后行股骨近端置换且影像随访超过12个月的患者。
- 记录患者人口学、手术和肿瘤学因素,采用Baker分类测量髋臼磨损,采用国际保肢学会分类对假体失败进行分类。
- 采用肌肉骨骼肿瘤学会评分和Harris髋关节评分进行功能评估。
主要发现
- 髋臼磨损患病率为28.6%。
- 5例(4.6%)需二次转为全髋关节置换,均为原发性骨肿瘤患者。
- 转移瘤患者无更高等级髋臼磨损或需翻修者。
- 髋臼磨损的显著危险因素为年龄小于40岁(P=0.035)和随访时间更长(63 vs 43个月,P=0.004)。
- 其他患者、手术或辅助治疗相关因素与髋臼翻修或髋臼磨损无关;患者队列脱位率为0.9%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Hemiarthroplasty megaprosthetic proximal femur reconstruction after tumor resection is a widespread procedure in orthopedic oncology. One potential complication is acetabular wear requiring secondary acetabular revision. The study's purpose is to investigate prevalence of acetabular erosion, secondary revisions, and potential risk factors. METHODS: We retrospectively identified 112 patients who underwent proximal femur replacement after resection of a malignant bone tumor and had radiological follow-up longer than 12 months. Patient demographic, surgical, and oncologic factors were recorded, acetabular wear was measured using the classification proposed by Baker, and prosthetic failure was classified using the International Society on Limb Salvage classification. Functional assessment was performed using the Musculoskeletal Tumor Society Score and Harris Hip Score. RESULTS: Prevalence of acetabular wear was 28.6%. Secondary conversion to total hip arthroplasty was required in 5 patients (4.6%), all treated for primary bone tumors. No patient treated for metastatic tumor had higher grade acetabular wear or required revision. Significant risk factors for the development of acetabular wear were age under 40 (P = .035) and longer follow-up (63 vs 43 months, P = .004). Other patient, surgical, or adjuvant treatment-related factors were not associated with acetabular revision or acetabular wear. The dislocation rate in the patient cohort was 0.9%. CONCLUSION: Bipolar hemiarthroplasty proximal femoral replacement represents a durable reconstruction after tumor resection. Hip instability is rare. Acetabular erosion is rare and can be successfully treated with conversion to total hip arthroplasty. Young patients with long-term survival over 10 years are at risk. In reconstruction for metastases, instability and acetabular wear are rare.
引用
- Theil C, Möllenbeck B, Gosheger G, et al. Acetabular Erosion After Bipolar Hemiarthroplasty in Proximal Femoral Replacement for Malignant Bone Tumors. J Arthroplasty. 2019. PMID: 31279599. doi:10.1016/j.arth.2019.06.014