文献速递关节外科

重新评估急性假体周围关节感染的现行临界值:现行阈值不敏感

Reevaluating Current Cutoffs for Acute Periprosthetic Joint Infection: Current Thresholds Are Insensitive.
PubMed 文献 · J Arthroplasty · 2019-06-27

本研究回顾性分析了2000至2017年治疗的218例急性假体周围关节感染(PJI)患者,评估国际共识会议推荐的血清C反应蛋白(CRP)、滑液白细胞计数(WBC)和多形核细胞百分比(PMN%)临界值(分别为100 mg/L、10,000 cell/μL和90%)的敏感性,并识别假阴性相关因素。结果显示CRP、滑液WBC和PMN%的总体敏感性分别为55.3%、59.6%和50.5%,凝固酶阴性葡萄球菌(CNS)感染是CRP假阴性的独立危险因素。作者认为现行急性PJI阈值可能漏诊约一半感染,需重新审视。

要点

  • 现行急性PJI的CRP、滑液WBC和PMN%阈值敏感性分别为55.3%、59.6%和50.5%。
  • CNS感染对CRP(37.5%)和WBC(55.6%)的敏感性最低,是CRP假阴性的独立危险因素。
  • 作者认为现行急性PJI阈值可能漏诊约一半感染,需重新审视。

核心结论

  • 现行急性PJI阈值可能漏诊约一半PJI,低毒力病原体如CNS可能是假阴性的原因,现行阈值需重新审视。

研究设计与样本

  • 回顾性综述2000至2017年治疗的218例急性PJI患者,急性PJI定义为距指数关节置换术不足6周,诊断基于假体周围组织或滑液样本中同一病原体的2次阳性培养。

主要发现

  • CRP、滑液WBC和PMN%对急性PJI的总体敏感性分别为55.3%、59.6%和50.5%。
  • CNS对CRP(37.5%)和WBC(55.6%)的敏感性最低。
  • CNS感染是CRP假阴性的独立危险因素。

关键数值与推荐

  • 国际共识会议推荐的急性PJI临界值:血清CRP 100 mg/L、滑液WBC 10,000 cell/μL、PMN% 90%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Diagnosing acute periprosthetic joint infection remains a challenge. Several studies have proposed different acute cutoffs resulting in the International Consensus Meeting recommending a cutoff of 100 mg/L, 10,000 cell/μL and 90% for serum C-reactive protein (CRP), synovial white blood cell count (WBC), and polymorphonuclear percentage (PMN%), respectively. However, establishing cutoffs are difficult as the control group is limited to rare early aseptic revisions, and performing aspiration in asymptomatic patients is difficult because of a fear of seeding a well-functioning joint arthroplasty. This study (1) assessed the sensitivity of current thresholds for acute periprosthetic joint infection (PJI) and (2) identified associated factors for false negatives. METHODS: We retrospectively reviewed patients with acute PJIs (n = 218), defined as less than 6 weeks from index arthroplasty, treated between 2000 and 2017. Diagnosis of PJI was based on 2 positive cultures of the same pathogen from the periprosthetic tissue or synovial fluid samples. Sensitivities of International Consensus Meeting cutoff values of CRP, synovial WBC, and PMN% were evaluated according to organism type. Multiple logistic regression analysis was performed to determine associated factors for false negatives. RESULTS: Overall, the sensitivity of CRP, synovial WBC, and PMN% for acute PJI was 55.3%, 59.6%, and 50.5%, respectively. Coagulase-negative Staphylococcus (CNS) demonstrated the lowest sensitivity for both CRP (37.5%) and WBC (55.6%). CNS infection was identified as an independent risk factor for false-negative CRP. CONCLUSIONS: Current thresholds for acute PJI may be missing approximately half of PJIs. Low virulent organisms, such as CNS, may be responsible for these false negatives. Current thresholds for acute PJI must be reexamined.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Xu C, Tan TL, Kuo FC, et al. Reevaluating Current Cutoffs for Acute Periprosthetic Joint Infection: Current Thresholds Are Insensitive. J Arthroplasty. 2019. PMID: 31307871. doi:10.1016/j.arth.2019.06.048

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。