文献速递关节外科创伤骨科

股骨距领可预防初次全髋关节置换术非骨水泥股骨假体周围早期假体周围骨折:一项具有生物力学验证的登记研究

A calcar collar is protective against early periprosthetic femoral fracture around cementless femoral components in primary total hip arthroplasty: a registry study with biomechanical validation.
PubMed 文献 · Bone Joint J · 2019-01-01

基于英国国家关节登记中心337 647例初次全髋关节置换术的多变量生存与回归分析,评估非骨水泥股骨柄设计特征与90天假体周围骨折翻修风险的关系,并用配对新鲜冰冻尸体股骨体外模型验证领的作用。早期假体周围骨折翻修率为0.34%(1180/337 647),其中44.0%(520/1180)发生在术后90天内;无领股骨柄、非砂砾喷砂表面和三锥度设计是植入物危险因素;体外模型中股骨距内侧领持续改善稳定性与抗骨折能力。

要点

  • 早期假体周围骨折翻修率为0.34%(1180/337 647),44.0%(520/1180)发生在术后90天内。
  • 植入物危险因素包括无领股骨柄、非砂砾喷砂表面和三锥度设计。
  • 体外模型中股骨距内侧领持续改善稳定性与抗骨折能力。

核心结论

  • 分析登记数据中的股骨柄设计特征有助于识别影响非骨水泥股骨柄周围早期假体周围骨折风险的植入物特征。
  • 股骨距上的领降低早期假体周围骨折风险,并经生物力学测试证实。

研究设计与样本

  • 纳入英国国家关节登记中心(NJR)337 647例初次全髋关节置换术,进行多变量生存与回归分析。
  • 使用配对新鲜冰冻尸体股骨体外模型评估非骨水泥全髋关节置换术中领的作用。

主要发现

  • 早期假体周围骨折翻修率为0.34%(1180/337 647),其中44.0%(520/1180)发生在术后90天内。
  • 植入物危险因素包括无领股骨柄、非砂砾喷砂表面和三锥度设计。
  • 体外模型中股骨距内侧领持续改善稳定性与抗骨折能力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to estimate the 90-day risk of revision for periprosthetic femoral fracture associated with design features of cementless femoral stems, and to investigate the effect of a collar on this risk using a biomechanical in vitro model. MATERIALS AND METHODS: A total of 337 647 primary total hip arthroplasties (THAs) from the United Kingdom National Joint Registry (NJR) were included in a multivariable survival and regression analysis to identify the adjusted hazard of revision for periprosthetic fracture following primary THA using a cementless stem. The effect of a collar in cementless THA on this risk was evaluated in an in vitro model using paired fresh frozen cadaveric femora. RESULTS: The prevalence of early revision for periprosthetic fracture was 0.34% (1180/337 647) and 44.0% (520/1180) occurred within 90 days of surgery. Implant risk factors included: collarless stem, non-grit-blasted finish, and triple-tapered design. In the in vitro model, a medial calcar collar consistently improved the stability and resistance to fracture. CONCLUSION: Analysis of features of stem design in registry data is a useful method of identifying implant characteristics that affect the risk of early periprosthetic fracture around a cementless femoral stem. A collar on the calcar reduced the risk of an early periprosthetic fracture and this was confirmed by biomechanical testing. This approach may be useful in the analysis of other uncommon modes of failure after THA. Cite this article: Bone Joint J 2019;101-B:779-786.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Lamb JN, Baetz J, Messer-Hannemann P, et al. A calcar collar is protective against early periprosthetic femoral fracture around cementless femoral components in primary total hip arthroplasty: a registry study with biomechanical validation. Bone Joint J. 2019. PMID: 31256663. doi:10.1302/0301-620X.101B7.BJJ-2018-1422.R1