关节镜下修复孤立性肩胛下肌全层撕裂:单排与双排缝线桥技术的对比
本研究纳入56例孤立性肩胛下肌全层撕裂且肌肉脂肪浸润≤II级的患者,分别行关节镜下单排(31例)或双排缝线桥(25例)修复。术后2年两组VAS、SSV、ASES、UCLA评分、肩胛下肌力量及主动活动度均较术前显著改善(P<.001),但组间无显著差异;随访MRA或CTA显示单排组再撕裂率13%(4/31)与双排组12%(3/25)无显著差异。结论认为两种技术均可获得满意的临床结果和结构完整性。
要点
- 孤立性肩胛下肌全层撕裂关节镜下修复后2年,单排与双排缝线桥技术临床评分组间无显著差异。
- 术后6个月MRA或CTA评估再撕裂率:单排组13%(4/31) vs 双排组12%(3/25),无显著差异。
- 两组术后VAS、SSV、ASES、UCLA、肩胛下肌力量及主动活动度均较术前显著改善(P<.001)。
核心结论
- 关节镜下单排修复与双排缝线桥修复孤立性肩胛下肌全层撕裂,在肌肉质量良好的患者中均获得满意的临床结果和结构完整性,组间无显著差异。
研究设计与样本
- 队列研究,证据等级3;纳入56例孤立性肩胛下肌全层撕裂且肩胛下肌脂肪浸润≤II级的患者,单排技术31例,双排缝线桥技术25例。
主要发现
- 术后2年,两组VAS、SSV、ASES、UCLA评分、肩胛下肌力量及主动活动度均较术前显著改善(P<.001)。
- 术后2年组间临床结局无显著差异:VAS 1.2 vs 1.1;SSV 91.3 vs 91.8;ASES 91.0 vs 91.4;UCLA 31.9 vs 32.1。
- 术后6个月MRA或CTA评估总体再撕裂率单排组13%(4/31) vs 双排组12%(3/25),无显著差异。
关键数值与推荐
- 单排组再撕裂率13%(4/31),双排组12%(3/25),组间无显著差异。
- 术后2年VAS单排组1.2 vs 双排组1.1;SSV单排组91.3 vs 双排组91.8;ASES单排组91.0 vs 双排组91.4;UCLA单排组31.9 vs 双排组32.1。
临床怎么用
- 对于孤立性肩胛下肌全层撕裂且脂肪浸润≤II级的患者,关节镜下单排修复或双排缝线桥修复均可获得满意的临床结果和结构完整性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: No clinical comparative study has addressed isolated subscapularis tears after arthroscopic repair with either single-row or double-row suture-bridge technique. PURPOSE/HYPOTHESIS: The purpose of this study is to compare clinical outcomes and structural integrity after arthroscopic repair of an isolated subscapularis full-thickness tear with either the single-row technique or the double-row suture-bridge technique. The authors hypothesized that there would be no significant differences in clinical outcomes and structural integrity between approaches. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This study included 56 patients who underwent arthroscopic repair of an isolated subscapularis full-thickness tear with grade II or less fatty infiltration in the subscapularis muscle with either a single-row technique (n = 31) or a double-row suture-bridge technique (n = 25). Functional outcomes were assessed with the visual analog scale (VAS) for pain, Subjective Shoulder Value (SSV), American Shoulder and Elbow Surgeons (ASES) score, the University of California, Los Angeles (UCLA) shoulder score, and active range of motion. Magnetic resonance arthrography (MRA) or computed tomographic arthrography (CTA) was performed 6 months after surgery to assess the structural integrity of the repaired tendon. RESULTS: At the 2-year follow-up, all scoring parameters applied (VAS, SSV, ASES, and UCLA), subscapularis strength, and active range of motion improved significantly in both groups as compared with preoperative values ( P < .001). However, there were no significant differences between groups in any of these clinical outcome measurements (VAS, 1.2 vs 1.1; SSV, 91.3 vs 91.8; ASES, 91.0 vs 91.4; UCLA, 31.9 vs 32.1). On follow-up MRA or CTA, the overall retear rate did not differ significantly between the single-row group (13%, 4 of 31) and the double-row group (12%, 3 of 25). CONCLUSION: Arthroscopic single-row repair and double-row suture-bridge repair of isolated full-thickness subscapularis tears both yielded satisfactory clinical outcomes and structural integrity with no significant differences among patients with good muscle quality.
引用
- Yoon JS, Kim SJ, Choi YR, et al. Arthroscopic Repair of the Isolated Subscapularis Full-Thickness Tear: Single- Versus Double-Row Suture-Bridge Technique. Am J Sports Med. 2019. PMID: 31042439. doi:10.1177/0363546519838281
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。