文献速递关节外科

原发性髋骨关节炎患者髋臼偏心距高度变异性影响髋臼磨锉——基于计算机断层扫描的解剖学研究

High Variability of Acetabular Offset in Primary Hip Osteoarthritis Influences Acetabular Reaming-A Computed Tomography-Based Anatomic Study.
PubMed 文献 · J Arthroplasty · 2019-04-01

本研究对131例原发性髋骨关节炎患者的CT与骨盆正位X线片进行三维髋臼与股骨测量,评估X线测量髋臼偏心距(AO)的准确性与可靠性,并模拟解剖性与传统磨锉技术下旋转中心(COR)的内移量。结果显示标准骨盆正位X线片可准确可靠评估AO,解剖性磨锉技术下植入物相关内移平均5.9±3.4 mm,传统磨锉技术下COR总内移平均6.8±2.9 mm,34%病例内移≥8 mm。

要点

  • 标准骨盆正位X线片可准确可靠评估髋臼偏心距(AO),且AO似乎与股骨形态和几何形状无关。
  • 解剖性磨锉技术下植入物相关内移平均5.9±3.4 mm,64髋(49%)无需磨锉至真臼底。
  • 传统磨锉技术下COR总内移平均6.8±2.9 mm,34%病例内移≥8 mm。

核心结论

  • 本研究强调原发性髋骨关节炎患者髋臼解剖存在变异性,AO可在传统X线片上准确可靠测定,且似乎与股骨形态和几何形状无关。
  • 根据所选磨锉技术,相当数量患者似乎存在髋臼杯过度内移的风险。

研究设计与样本

  • 连续纳入131例原发性髋骨关节炎患者的CT扫描与相应X线片,使用经过验证的软件进行三维髋臼与股骨测量。
  • 模拟半球形压配杯植入,比较解剖性与传统磨锉技术,并评估AO的相应变化。

主要发现

  • 标准骨盆正位X线片与CT相比可准确可靠评估AO。
  • 髋臼杯置于最外侧位置(解剖性磨锉技术)导致植入物相关内移平均5.9±3.4 mm。
  • 解剖性髋臼杯放置时64髋(49%)无需磨锉至真臼底。
  • 传统磨锉技术下COR总内移(植入物相关与磨锉相关)为6.8±2.9 mm,34%病例内移≥8 mm。

关键数值与推荐

  • 解剖性磨锉技术:植入物相关内移平均5.9±3.4 mm。
  • 传统磨锉技术:COR总内移平均6.8±2.9 mm,34%病例内移≥8 mm。
  • 解剖性髋臼杯放置时64髋(49%)无需磨锉至真臼底。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The objectives of the present study were to (1) evaluate the accuracy and reliability of native acetabular offset (AO) measurements performed on conventional supine anterior-posterior (ap) pelvis radiographs with reference to computed tomography (CT) in patients with end-stage hip osteoarthritis (OA); (2) determine the minimum and maximum amount of medialization of the center of rotation (COR) simulating different reaming techniques; and (3) identify patients at increased risk of excessive medialization of the COR. METHODS: A consecutive series of corresponding 131 CT scans and radiographs of patients with primary hip OA was evaluated using validated software for three-dimensional acetabular and femoral measurements. We simulated the implantation of a hemispherical press-fit cup comparing anatomic and conventional reaming techniques and assessed corresponding changes in AO. RESULTS: Standardized ap pelvis radiographs allowed for an accurate and reliable assessment of AO compared with CT. Cup placement in the most lateral position (anatomic reaming technique) resulted in a mean implant-related medialization of 5.9 ± 3.4 mm. Anatomic cup placement did not require reaming to the true floor in 64 hips (49%). With the conventional reaming technique, the total medialization of the COR (implant-related and reaming-related) was 6.8 ± 2.9, with 34% of cases having a medialization ≥8 mm. CONCLUSION: The present study highlights the variability of acetabular anatomy in patients with primary OA. AO can be accurately and reliably determined on conventional radiographs and appears to be independent of femoral shape and geometry. Depending on the preferred reaming technique a substantial number of patients appear at risk for excessive cup medialization.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Merle C, Innmann MM, Waldstein W, et al. High Variability of Acetabular Offset in Primary Hip Osteoarthritis Influences Acetabular Reaming-A Computed Tomography-Based Anatomic Study. J Arthroplasty. 2019. PMID: 31122846. doi:10.1016/j.arth.2019.03.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。