文献速递关节外科

大腿周径是否影响直接前入路全髋关节置换术中髋臼假体的定位

Does the thigh circumference affect the positioning of the acetabular component when using the direct anterior approach in total hip arthroplasty?
PubMed 文献 · Bone Joint J · 2019-01-01

该回顾性研究纳入155例连续直接前入路全髋关节置换术,按大腿周径四分位分组,发现最大20cm周径四分位组髋臼假体倾斜角较最小四分位组平均大5.96°、前倾角平均大2.92°,但假体位置不良风险无显著差异,结论为大腿周径较大患者可安全行直接前入路全髋关节置换术。

要点

  • 大腿周径最大20cm四分位组(59cm至78cm)髋臼倾斜角较最小四分位组平均大5.96°(95%CI 2.99°至8.93°;p<0.001)。
  • 同一组前倾角较最小四分位组平均大2.92°(95%CI 0.47°至5.37°;p=0.020)。
  • 下肢长度差异和股骨偏心距在各组间无显著差异,假体位置不良风险无变化。

核心结论

  • 随着大腿周径增加,髋臼假体倾斜角和前倾角呈相关性增大,但假体位置不良风险无变化。
  • 大腿周径较大的患者可采用直接前入路行全髋关节置换术,且无髋臼假体位置不良风险。

研究设计与样本

  • 回顾性审查前瞻性收集的数据,纳入148例患者共155例连续直接前入路全髋关节置换术,由学术医疗中心单一接受专科培训的外科医生完成。
  • 术前于髂前上棘远端10cm、20cm、30cm处测量大腿周径并按四分位分组。
  • 由两名盲法评估者评估髋臼假体倾斜角和前倾角、影像学下肢长度差异及股骨偏心距;影像学结果按连续变量和基于Lewinnek安全区的二分类变量分析。

主要发现

  • 三个大腿周径组均观察到相似趋势。
  • 多变量分析中,最大20cm大腿周径四分位组(59cm至78cm)倾斜角较最小四分位组平均大5.96°(95%CI 2.99°至8.93°;p<0.001)。
  • 最大20cm大腿周径四分位组前倾角较最小四分位组平均大2.92°(95%CI 0.47°至5.37°;p=0.020)。
  • 下肢长度差异或股骨偏心距未见显著差异。

关键数值与推荐

  • 大腿周径按髂前上棘远端10cm、20cm、30cm处测量并分为四分位。
  • 影像学结果按连续变量和基于Lewinnek安全区的二分类变量评估。
  • 最大20cm大腿周径四分位组范围为59cm至78cm。

临床怎么用

  • 原文结论指出,大腿周径较大的患者可采用直接前入路行全髋关节置换术,且无髋臼假体位置不良风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The hypothesis of this study was that thigh circumference, distinct from body mass index (BMI), may be associated with the positioning of components when undertaking total hip arthroplasty (THA) using the direct anterior approach (DAA), and that an increased circumference might increase the technical difficulty. PATIENTS AND METHODS: We performed a retrospective review of prospectively collected data involving 155 consecutive THAs among 148 patients undertaken using the DAA at an academic medical centre by a single fellowship-trained surgeon. Preoperatively, thigh circumference was measured at 10 cm, 20 cm, and 30 cm distal to the anterior superior iliac spine, in quartiles. Two blinded reviewers assessed the inclination and anteversion of the acetabular component, radiological leg-length discrepancy, and femoral offset. The radiological outcomes were considered as continuous and binary outcome variables based on Lewinnek's 'safe zone'. RESULTS: Similar trends were seen in all three thigh circumference groups. In multivariable analyses, patients in the largest 20 cm thigh circumference quartile (59 cm to 78 cm) had inclination angles that were a mean of 5.96° larger (95% confidence interval (CI) 2.99° to 8.93°; p < 0.001) and anteversion angles that were a mean of 2.92° larger (95% CI 0.47° to 5.37°; p = 0.020) than the smallest quartile. No significant differences were noted in leg-length discrepancy or offset. CONCLUSION: There was an associated increase in inclination and anteversion as thigh circumference increased, with no change in the risk of malpositioning the components. THA can be performed using the DAA in patients with large thigh circumference without the risk of malpositioning the acetabular component. Cite this article: Bone Joint J 2019;101-B:529-535.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Jacobs CA, Kusema ET, Keeney BJ, et al. Does the thigh circumference affect the positioning of the acetabular component when using the direct anterior approach in total hip arthroplasty? Bone Joint J. 2019. PMID: 31038997. doi:10.1302/0301-620X.101B5.BJJ-2018-0847.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。