文献速递关节外科

翻修全膝关节置换术中干骺端缺损增强用骨整合套袖的临床与影像学5年随访

Osteointegrative Sleeves for Metaphyseal Defect Augmentation in Revision Total Knee Arthroplasty: Clinical and Radiological 5-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2019-04-16

本研究分析了67例连续患者(68例翻修全膝关节置换术)在AORI 2a、2b和3型缺损中采用无骨水泥干骺端套袖的中期结果和假体生存率。平均随访5.0年,无菌生存率为93.6%,排除初始技术问题后达98%,WOMAC和KSS评分分别显著改善64.8分和25.8分(P < .001)。模块化套袖设计允许关节线重建接近解剖水平。

要点

  • 无骨水泥干骺端套袖在AORI 2a、2b和3型缺损中5年无菌生存率为93.6%,排除初始技术问题后为98%。
  • WOMAC和KSS评分分别显著改善64.8分和25.8分(P < .001)。
  • 平均关节线较解剖水平低0.36 mm,模块化套袖设计允许接近解剖水平的关节线重建。

核心结论

  • 在平均5.0年随访时,无骨水泥骨整合套袖用于AORI 2a、2b和3型干骺端缺损固定,即使先前有翻修史也能获得持续假体固定。
  • 排除初始技术问题后,5年无菌生存率为98%。
  • 模块化套袖设计允许关节线重建接近解剖水平。

研究设计与样本

  • 研究纳入2011年至2014年间67例连续患者(68例翻修全膝关节置换术),均接受无骨水泥干骺端套袖。
  • 平均随访5.0年,平均年龄68.5岁,平均体重指数31.4 kg/m2。
  • 采用既定评分系统评估临床和影像学结果,计算生存率并分析失败原因。

主要发现

  • 2例患者(4.3%)因二期再植入后深部感染在术后早期移除套袖。
  • 剩余假体持续功能良好,无菌生存率为93.6%;排除因骨质量差导致的初始技术问题后,无菌生存率高达98%。
  • WOMAC评分显著改善64.8分,KSS评分显著改善25.8分(P < .001)。
  • 10例患者(29.4%)观察到骨干射线可透线,但无松动怀疑。
  • 平均关节线较解剖水平低0.36 mm。

关键数值与推荐

  • 无菌生存率93.6%(剩余假体持续功能良好),排除初始技术问题后为98%。
  • WOMAC评分改善64.8分,KSS评分改善25.8分(P < .001)。
  • 10例患者(29.4%)出现骨干射线可透线,无松动怀疑。
  • 平均关节线较解剖水平低0.36 mm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cementless metaphyseal implant fixation of revision total knee arthroplasty has encouraging early results. We analyzed midterm results and implant survival of osteointegrative augments in Anderson Orthopedic Research Institute (AORI) type 2a, 2b, and 3 defects. Reasons for implant failure were explored and the potential for anatomic joint line reconstruction evaluated. METHODS: Sixty-seven consecutive patients (68 revision total knee arthroplasties) received cementless metaphyseal sleeves between 2011 and 2014. The mean follow-up was 5.0 years, mean age was 68.5 years, and mean body mass index was 31.4 kg/m2. The clinical and radiographic results were determined using established scoring systems. Additionally, the survival rate was calculated and reasons for failure were analyzed. RESULTS: In 2 patients (4.3%), sleeves had to be removed early postoperatively for deep infection after second-stage reimplantation. With continuously functioning remaining implants, the aseptic survival rate was 93.6%. Cleared up for initial technical issues due to poor bone quality, it is as high as 98%. The scores remained to be significantly improved by 64.8 points (Western Ontario and McMaster Universities Osteoarthritis Index) and 25.8 points (Knee Society score) (P < .001). In 10 patients (29.4%), diaphyseal radiolucencies were observed without suspicion of loosening. The mean joint line was noted to be 0.36 mm lower to the anatomic level. CONCLUSION: At a mean follow-up of 5.0 years, cementless osteointegrative sleeves for metaphyseal fixation in AORI 2a, AORI 2b, and AORI 3 defects yielded continuous implant fixation even in cases with preceding revisions. The cleared up aseptic survival rate was 98% at 5 years. The modular sleeve design allowed joint line reconstruction near the anatomic level.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Wirries N, Winnecken HJ, Lewinski GV, et al. Osteointegrative Sleeves for Metaphyseal Defect Augmentation in Revision Total Knee Arthroplasty: Clinical and Radiological 5-Year Follow-Up. J Arthroplasty. 2019. PMID: 31079992. doi:10.1016/j.arth.2019.04.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。