文献速递关节外科

功能良好的金属对金属髋关节表面置换患者是否需要终末器官监测?一项心脏MRI调查

Is end-organ surveillance necessary in patients with well-functioning metal-on-metal hip resurfacings? A cardiac MRI survey.
PubMed 文献 · Bone Joint J · 2019-01-01

本研究用心脏磁共振(CMR)评估功能良好的金属对金属髋关节表面置换术(MoMHRA)患者的心脏功能或组织构成是否受影响,并与对照组比较,同时分析金属离子水平与心脏功能或结构参数的相关性。共纳入30名无显著心脏病史的参与者:20例功能良好的MoMHRA患者(平均术后随访8.3年;10例单侧、10例双侧;17男3女)和10例病例匹配的非MoM全髋关节置换术对照组(6男4女)。MoMHRA患者无临床显著心脏功能异常,但右、左心室舒张末期容积指数较大,T2时间轻度缩短,且较高金属离子水平与较大左心室容积和较短T2时间相关。

要点

  • 功能良好的MoMHRA患者无临床显著心脏功能异常。
  • MoMHRA患者左心室舒张末期容积指数74 ml/m2 vs 对照组67 ml/m2(p=0.045),右心室80 ml/m2 vs 71 ml/m2(p=0.02)。
  • MoMHRA患者T2时间中位数49 ms vs 对照组54 ms(p=0.0003),较高金属离子水平与较大左心室容积和较短T2时间相关。

核心结论

  • 功能良好的MoMHRA患者心脏功能未受临床不良影响,但现代影像可显示心脏结构和功能的细微变化;这些变化与全身离子测量相关,可能是磨损碎屑沉积的结果;需要更长期的纵向研究以确定心脏功能是否会受影响。

研究设计与样本

  • 纳入30名无显著心脏病史的参与者:20例功能良好的MoMHRA患者(平均术后随访8.3年;10例单侧、10例双侧;17男3女)和10例病例匹配的非MoM全髋关节置换术对照组(6男4女)。
  • 全队列手术时平均年龄50.6岁(范围41.0至64.0岁)。
  • 测量血清钴和铬水平,所有患者接受CMR成像,包括电影、T2*测量、T1和T2 mapping、晚期钆增强和应变测量。

主要发现

  • MoMHRA患者无临床显著心脏功能异常。
  • MoMHRA患者左心室舒张末期容积指数74 ml/m2 vs 对照组67 ml/m2(p=0.045),右心室80 ml/m2 vs 71 ml/m2(p=0.02)。
  • MoMHRA患者T2时间中位数49 ms vs 对照组54 ms(p=0.0003)。
  • 较高金属离子水平与较大左心室容积和较短T2时间相关。

局限性

  • 需要更长期的纵向研究以确定心脏功能是否会受影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. PATIENTS AND METHODS: In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements. RESULTS: None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m2vs 67 ml/m2, p = 0.045; right ventricular: 80 ml/m2vs 71 ml/m2, p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time. CONCLUSION: Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. Cite this article: Bone Joint J 2019;101-B:540-546.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Juneau D, Grammatopoulos G, Alzahrani A, et al. Is end-organ surveillance necessary in patients with well-functioning metal-on-metal hip resurfacings? A cardiac MRI survey. Bone Joint J. 2019. PMID: 31039002. doi:10.1302/0301-620X.101B5.BJJ-2018-1478.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。