文献速递关节外科创伤骨科

解剖型与反式肩关节置换中非骨水泥短肱骨假体的中期影像学结果

Mid-term radiological results of a cementless short humeral component in anatomical and reverse shoulder arthroplasty.
PubMed 文献 · Bone Joint J · 2019-01-01

该回顾性综述纳入100例肩关节置换(35例解剖型TSA、65例反式RSA),平均随访3.8年,评估非骨水泥短肱骨假体的影像学肱骨骨改变与机械失败率。大结节应力遮挡14例(TSA 2例、RSA 12例),内侧肱骨距吸收23例(TSA 7例、RSA 16例),无因松动翻修或影像学松动,9例因感染、肱骨托骨折、无菌性盂松动和不稳定再手术。作者认为该短柄假体在中期随访中肱骨侧不良影像学表现发生率低,数据未提出对TSA或RSA使用短柄的担忧。

要点

  • 100例肩关节置换(35例TSA、65例RSA)平均随访3.8年,评估非骨水泥短肱骨假体。
  • 大结节应力遮挡14例(TSA 2例、RSA 12例),内侧肱骨距吸收23例(TSA 7例、RSA 16例)。
  • 无因松动翻修或影像学松动,无假体周围骨折,9例再手术。

核心结论

  • 作者认为该特定非骨水泥短肱骨假体在TSA或RSA中期随访中肱骨侧不良影像学表现发生率低,数据未提出对TSA或RSA使用短柄的担忧。

研究设计与样本

  • 回顾性综述,纳入100例肩关节置换(35例解剖型TSA和65例反式RSA),评估非骨水泥短肱骨假体植入后的影像学肱骨骨改变与机械失败率。
  • 随访时间平均3.8年(范围3至8.3年),手术时平均年龄68岁(范围31至90岁),平均体重指数32.7 kg/m2(范围17.3至66.4)。

主要发现

  • 大结节应力遮挡见于14例肩关节(TSA 2例、RSA 12例),其中轻度9例、中度2例、重度3例。
  • 内侧肱骨距吸收见于23例肩关节(TSA 7例、RSA 16例),其中轻度21例、中度2例。
  • 无肱骨假体因松动翻修或影像学判定为松动,无假体周围骨折发生。
  • 9例肩关节再手术,原因包括感染(3例)、肱骨托骨折(2例)、无菌性盂松动(1例)和不稳定(3例)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). PATIENTS AND METHODS: A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4). RESULTS: Greater tuberosity stress shielding was noted in 14 shoulders (two TSA and 12 RSA) and was graded as mild in nine, moderate in two, and severe in three. Medial calcar resorption was noted in 23 shoulders (seven TSA and 16 RSA), and was graded as mild in 21 and moderate in two. No humeral components were revised for loosening or considered to be loose radiologically. Nine shoulders underwent reoperation for infection (n = 3), fracture of the humeral tray (n = 2), aseptic glenoid loosening (n = 1), and instability (n = 3). No periprosthetic fractures occurred. CONCLUSION: Implantation of this particular short cementless humeral component at the time of TSA or RSA was associated with a low rate of adverse radiological findings on the humeral side at mid-term follow-up. Our data do not raise any concerns regarding the use of a short stem in TSA or RSA. Cite this article: Bone Joint J 2019;101-B:610-614.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Aibinder WR, Bartels DW, Sperling JW, et al. Mid-term radiological results of a cementless short humeral component in anatomical and reverse shoulder arthroplasty. Bone Joint J. 2019. PMID: 31039055. doi:10.1302/0301-620X.101B5.BJJ-2018-1374.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。