文献速递关节外科小儿骨科

全髋关节置换术对单侧发育性髋关节发育不良(Crowe IV型)患者下肢轴向对线的影响

Effects of Total Hip Arthroplasty on Axial Alignment of the Lower Limb in Patients with Unilateral Developmental Hip Dysplasia (Crowe type IV).
PubMed 文献 · J Arthroplasty · 2019-04-20

本研究回顾性分析50例接受全髋关节置换术(髋臼杯置于解剖位置)的单侧发育性髋关节发育不良(Crowe IV型)成人患者,测量术前、术后即刻及术后2年的下肢轴向对线参数。结果显示术后即刻患侧下肢外翻倾斜显著减小,股骨偏心距、胫股角、髋膝踝角及机械侧远端股骨角显著增大,术后2年与术后即刻无显著差异;对侧下肢轴向对线仅轻微改变。

要点

  • 患侧下肢术前存在显著外翻畸形,术后即刻外翻倾斜显著减小。
  • 术后即刻胫股角、髋膝踝角、股骨偏心距及机械侧远端股骨角显著增大,术后2年维持稳定。
  • 对侧下肢术后机械轴偏移及胫骨近端内侧角稍减小,而机械侧远端股骨角、胫股角及髋膝踝角增大。

核心结论

  • 在髋臼假体置于解剖髋中心水平的全髋关节置换术后,患侧下肢轴向对线立即改变,外翻倾斜显著减小。
  • 该手术仅轻微改变对侧下肢的轴向对线。

研究设计与样本

  • 回顾性分析50例接受全髋关节置换术的单侧发育性髋关节发育不良(Crowe IV型)成人患者的病历资料,髋臼杯置于解剖位置。
  • 测量术前、术后即刻及术后2年的机械轴偏移、胫股角、股骨偏心距、髋膝踝角、机械侧远端股骨角、机械侧胫骨近端内侧角、股骨内髁高度、股骨外髁高度及下肢延长长度,并从病历记录中获取股骨截骨段长度。

主要发现

  • 患侧下肢术前机械轴偏移、胫股角、髋膝踝角及机械侧远端股骨角显示显著外翻畸形。
  • 患侧下肢术后即刻机械轴偏移和外翻倾斜较术前显著减小,而胫股角、髋膝踝角、股骨偏心距及机械侧远端股骨角较术前显著增大(P < 0.05)。
  • 上述参数在术后即刻与术后2年之间无显著差异(P > 0.05)。
  • 患侧肢体平均延长2.54 cm(范围0至5.35 cm),股骨截骨段平均长度3.56 cm(范围2.03至5.74 cm)。
  • 对侧下肢术后机械轴偏移和胫骨近端内侧角较术前稍减小,而机械侧远端股骨角、胫股角及髋膝踝角增大。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to evaluate the influence of total hip arthroplasty on axial alignment of the lower limb in adults with unilateral developmental hip dysplasia (Crowe type IV). METHODS: We retrospectively reviewed medical records of 50 adults who underwent total hip arthroplasty, in which the acetabular cup was placed in the anatomical position. The following parameters were measured before surgery, immediately after surgery, and two years later: mechanical axis deviation (MAD), tibiofemoral angle (TFA), femoral offset, hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (LDFA), mechanical medial proximal tibial angle, height of medial femoral condyle, height of lateral femoral condyle, and leg lengthening. Length of the resected femoral segment was also recorded from medical records. RESULTS: Preoperative MAD, TFA, HKA, and LDFA of the ipsilateral lower limb showed significant valgus deformity. MAD of the ipsilateral lower limb and valgus inclination were significantly smaller immediately after surgery than before, while TFA, HKA, femoral offset, and LDFA were significantly larger (P < 0.05). These parameters did not differ significantly between immediately after surgery and two years later (P > 0.05). Ipsilateral extremities were extended by a mean of 2.54 cm (range, 0 to 5.35 cm). The mean length of the femoral resected segment was 3.56 cm (range, 2.03 to 5.74 cm). The contralateral lower limb showed marginally smaller MAD and medial proximal tibial angle after surgery than before, but larger LDFA, TAF, and HKA. CONCLUSIONS: In patients with developmental hip dysplasia who underwent total hip arthroplasty with placement of the acetabular component at the level of the anatomic hip center, axial alignment of the ipsilateral lower limb was immediately altered, and valgus inclination was significantly reduced. The procedure only slightly altered the axial alignment of the contralateral lower limb.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Zhao HY, Kang PD, Shi XJ, et al. Effects of Total Hip Arthroplasty on Axial Alignment of the Lower Limb in Patients with Unilateral Developmental Hip Dysplasia (Crowe type IV). J Arthroplasty. 2019. PMID: 31103361. doi:10.1016/j.arth.2019.04.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。