Alpha-防御素试验在炎症性疾病患者中诊断假体周围关节感染的诊断准确性
本研究回顾性分析了2014至2017年间在单一医疗系统内因炎症性疾病行翻修全髋/膝关节置换术且术前有Alpha-防御素结果的41例患者,按肌肉骨骼感染学会标准分类感染与否。Alpha-防御素诊断假体周围关节感染的敏感性为93%、特异性为100%、阳性预测值为100%、阴性预测值为96%、准确性为97%,1例多发性肌炎患者出现假阴性。结论认为Alpha-防御素在炎症性疾病患者中诊断假体周围关节感染仍具有高准确性。
要点
- 在炎症性疾病患者中,Alpha-防御素诊断假体周围关节感染的敏感性为93%、特异性为100%。
- 阳性预测值为100%,阴性预测值为96%,准确性为97%。
- 1例多发性肌炎患者出现假阴性结果。
核心结论
- Alpha-防御素在炎症性疾病患者中诊断假体周围关节感染仍具有高准确性。
- Alpha-防御素试验在炎症性疾病患者中诊断假体周围关节感染可提供高准确性的有用信息。
研究设计与样本
- 回顾性综述,纳入2014至2017年在单一医疗系统内因炎症性疾病行翻修全髋/膝关节置换术且术前有Alpha-防御素结果的41例患者。
- 纳入标准为因炎症性疾病接受一期翻修、二期翻修第一阶段或清创冲洗且术前有Alpha-防御素结果者。
- 排除接受二期手术、间隔物更换、肌肉骨骼感染学会标准不充分或术后早期假体周围关节感染者。
- 按肌肉骨骼感染学会标准将病例分类为感染或非感染。
主要发现
- Alpha-防御素诊断假体周围关节感染的敏感性为93%。
- 特异性为100%。
- 阳性预测值为100%。
- 阴性预测值为96%。
- 准确性为97%,1例多发性肌炎患者出现假阴性结果。
关键数值与推荐
- 敏感性93%、特异性100%、阳性预测值100%、阴性预测值96%、准确性97%,基于41例炎症性疾病患者。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The alpha-defensin test has been reported to have high accuracy to diagnose periprosthetic joint infection (PJI). There are remaining concerns about the utility of the test in patients with inflammatory diseases. The purpose of this study is to determine sensitivity and specificity of laboratory-based alpha-defensin in diagnosing PJI in patients with systemic inflammatory disease in revision total hip/knee arthroplasty. METHODS: A retrospective review was conducted of 1374 cases who underwent revision total hip/knee arthroplasty at a single healthcare system from 2014 to 2017. Cases with inflammatory diseases who received a 1-stage revision arthroplasty, the first stage of 2-stage revision arthroplasty, or irrigation and debridement with available preoperative alpha-defensin results were included. Patients who received a second-stage procedure, spacer exchange, who had insufficient Musculoskeletal Infection Society criteria, or with early postoperative PJI were excluded from this study. Cases were classified as infected or not according to Musculoskeletal Infection Society criteria. A total of 41 cases met the inclusion criteria. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of alpha-defensin to diagnose PJI were calculated. RESULTS: The alpha-defensin test demonstrated a sensitivity of 93%, a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 96%, and an accuracy of 97% for diagnosing PJI. There was 1 patient with polymyositis who had a false-negative result. CONCLUSION: Alpha-defensin had high accuracy for diagnosing PJI even in inflammatory diseases. The alpha-defensin test provides useful information with high accuracy in diagnosing PJI in patients with inflammatory diseases.
引用
- Miyamae Y, George J, Klika AK, et al. Diagnostic Accuracy of the Alpha-Defensin Test for Periprosthetic Joint Infection in Patients With Inflammatory Diseases. J Arthroplasty. 2019. PMID: 31122850. doi:10.1016/j.arth.2019.04.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。