失败的金属对金属全髋关节置换翻修术:203例连续病例的中期结局
本研究评估了188例患者(203髋)因金属对金属全髋关节置换失败而接受翻修术的中期结局。翻修后Harris髋关节评分从53.6改善至73.5(P<.001),疼痛评分从17.2改善至32.8(P<.001),但再手术率为14%,再翻修率为7.9%,假瘤病例再翻修率显著更高。
要点
- 翻修后Harris髋关节评分和疼痛评分均显著改善(P<.001)。
- 再手术率为14%,再翻修率为7.9%,假瘤病例再翻修率显著更高。
- 4.2年全因生存率为90.5%,金属离子水平翻修后显著下降。
核心结论
- 失败的金属对金属全髋关节置换翻修术可改善临床结局,但存在显著的手术挑战和并发症,尤其在软组织损伤和假瘤病例中。
研究设计与样本
- 研究评估了188例患者(203髋)因金属对金属全髋关节置换失败而接受翻修术的病例,翻修时平均年龄60岁,女性112髋(55%),男性91髋(45%),初次全髋关节置换至失败的平均间隔为4.9年(范围0-18年),髋臼组件在183例(92%)中进行了翻修。
主要发现
- 翻修后平均随访4.2年,Harris髋关节评分从翻修前53.6改善至末次随访73.5(P<.001)。
- 疼痛评分从翻修前17.2显著改善至翻修后32.8(P<.001)。
- 28髋(14%)发生再手术,16髋(7.9%)需要再翻修,再翻修最常见原因为无菌性松动(5例)、脱位(3例)、感染(2例)和髂腰肌腱炎(2例)。
- 假瘤病例的再翻修率显著更高,超多孔杯的生存率无差异,3髋需要再翻修至定制三翼组件。
- 4.2年全因生存率为90.5%,翻修后金属离子水平显著下降。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Metal-on-metal (MoM) revisions have shown high rates of complications from aseptic loosening, deep infection, and dislocation. The purpose of this study is to report on outcomes and complications of a large consecutive series of patients who were revised for failed MoM total hip arthroplasty (THA). METHODS: We evaluated 188 patients (203 hips) who underwent revisions of failed MoM THA. Mean age at the revision was 60 years old. Gender was female in 112 hips (55%) and male in 91 hips (45%). Mean interval to failure after primary THA was 4.9 years (range, 0-18 years). The acetabular component was revised in 183 cases (92%). Clinical outcomes assessed included pain score and Harris hip score. RESULTS: Mean follow-up from revision was 4.2 years. Harris hip score improved from 53.6 pre-revision to 73.5 at most recent follow-up (P < .001). Pain level significantly improved from 17.2 pre-revision to 32.8 post-revision (P < .001). Reoperations occurred in 28 (14%) hips. Re-revision was required in 16 hips (7.9%). The most common reasons for re-revision were aseptic loosening (5), dislocation (3), infection (2), and iliopsoas tendonitis (2). Re-revision was significantly higher in cases of pseudotumor. There was no difference in survival with ultraporous cups. Three hips required re-revision to custom triflange components. All-cause survival was 90.5% at 4.2 years. Metal ion levels significantly declined after revision. CONCLUSION: Revisions of failed MoM THA showed improvements in clinical outcomes, but present significant surgical challenges and complications especially in cases with soft tissue damage and pseudotumor.
引用
- Crawford DA, Adams JB, Morris MJ, et al. Revision of Failed Metal-on-Metal Total Hip Arthroplasty: Midterm Outcomes of 203 Consecutive Cases. J Arthroplasty. 2019. PMID: 31053470. doi:10.1016/j.arth.2019.04.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。