文献速递关节外科

接受平衡的全膝关节置换术的患者满意度更高吗?

Are Patients More Satisfied With a Balanced Total Knee Arthroplasty?
PubMed 文献 · J Arthroplasty · 2019-03-19

这项多中心研究纳入318例初次全膝关节置换术患者,分为传感器引导组与术者引导组,术后6周和6个月填写遗忘关节评分与2011年膝关节协会满意度问卷;传感器引导组定量平衡膝比例显著更高(84.0%),且平衡组患者两项结局评分均显著更优。

要点

  • 传感器引导组定量平衡膝比例为84.0%,显著高于术者引导组约50%。
  • 平衡组患者在遗忘关节评分和2011年膝关节协会满意度问卷上均显著优于非平衡组。
  • 术者引导组中约50%的病例达到定量平衡。

核心结论

  • 全膝关节置换术中采用传感器反馈可使手术更可重复,获得更高比例的平衡患者,而平衡患者的临床结局优于非平衡患者。

研究设计与样本

  • 多中心研究,共纳入318例符合条件的患者,分为传感器引导全膝关节置换术组或术者引导全膝关节置换术组。
  • 传感器引导组依据仪器化胫骨试模组件测得的间室胫股载荷测量进行定量平衡;术者引导组按术者标准手工技术平衡,术者对传感器测量值设盲。
  • 患者对分组设盲,在术后6周和6个月填写经验证的遗忘关节评分和2011年膝关节协会满意度问卷。
  • 分析时将受试者合并,并根据整个活动范围内内外侧载荷差异所反映的软组织平衡状态进行分层。

主要发现

  • 术者引导组中约50%的病例达到定量平衡膝。
  • 传感器引导组观察到显著更多的平衡膝(84.0%)。
  • 对于两项结局指标,平衡组患者报告的结局评分均显著更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patient-reported outcome measures are increasingly recognized as an important tool in quantifying the clinical success of arthroplasty surgery. The aim of this study is to measure post-operative joint awareness and satisfaction in patients with and without a quantitatively balanced knee following primary total knee arthroplasty (TKA). METHODS: In this multi-center study, a total of 318 eligible patients were assigned to one of the 2 patient groups: sensor-guided TKA or surgeon-guided TKA. In the sensor-guided group, quantitative balancing was performed according to intercompartmental tibiofemoral load measurements measured by an instrumented tibial trial component. In contrast, for the surgeon-guided group, the knees were balanced according to the surgeons' standard manual techniques while blinding the surgeon to the sensor measurements. Patients were blinded to their allocation and filled out the validated Forgotten Joint Score and 2011 Knee Society Satisfaction questionnaires at 6 weeks and 6 months. For the purposes of this study, the subjects were pooled and stratified by their state of soft tissue balance, based on the mediolateral load differential through the range of motion. RESULTS: In the surgeon-guided group, approximately 50% of the cases yielded a quantitatively balanced knee. Significantly more balanced knees were observed in the sensor-guided group (84.0%). More importantly, for both outcome measures, the balanced group of patients reported significantly better outcomes scores. CONCLUSION: This demonstrates that using sensor feedback during knee arthroplasty surgery results in a more reproducible procedure, resulting in a higher percentage of balanced patients who in turn demonstrate superior clinical outcomes compared to unbalanced patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Golladay GJ, Bradbury TL, Gordon AC, et al. Are Patients More Satisfied With a Balanced Total Knee Arthroplasty? J Arthroplasty. 2019. PMID: 31079993. doi:10.1016/j.arth.2019.03.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。