文献速递骨质疏松与代谢性骨病创伤骨科

基于第二代高分辨率外周定量CT图像的均质化和微观有限元分析预测桡骨远端失效载荷的验证

Validation of distal radius failure load predictions by homogenized- and micro-finite element analyses based on second-generation high-resolution peripheral quantitative CT images.
PubMed 文献 · Osteoporos Int · 2019-04-17

研究对22根尸体桡骨远端20毫米节段行第二代高分辨率外周定量CT扫描后力学测试,建立标准化的微观有限元和均质化有限元模型识别材料参数;在20毫米节段,微观有限元(R²=0.969,斜率=1.035)和均质化有限元(R²=0.966,斜率=0.890)预测与实测失效载荷一致;限制至临床推荐10毫米区域,微观有限元仍准确(R²=0.955,斜率=1.021),均质化有限元精确但倾向高估(R²=0.952,斜率=0.780)。

要点

  • 采用本研究方法和参数,微观有限元和均质化有限元模型均可准确预测桡骨远端失效载荷。
  • 20毫米节段实测失效载荷与微观有限元(R²=0.969,斜率=1.035)和均质化有限元(R²=0.966,斜率=0.890)结果一致。
  • 10毫米临床区域均质化有限元预测精确但倾向高估失效载荷(R²=0.952,斜率=0.780)。

核心结论

  • 采用本研究开发的方法和参数,使用微观有限元或均质化有限元模型均可准确预测桡骨远端失效载荷。

研究设计与样本

  • 研究使用第二代高分辨率外周定量CT扫描22根尸体桡骨的远端20毫米节段,扫描后切除节段行力学测试。
  • 基于扫描图像建立微观有限元和均质化有限元模型,通过比较预测与实测结果识别所需材料参数。
  • 使用识别参数后将模型裁剪至临床研究推荐的10毫米区域,测试其失效载荷预测性能。

主要发现

  • 材料参数识别后,20毫米节段实测失效载荷与微观有限元模型结果高度一致(R²=0.969,斜率=1.035)。
  • 20毫米节段实测失效载荷与均质化有限元模型结果高度一致(R²=0.966,斜率=0.890)。
  • 限制至临床10毫米区域,微观有限元仍准确预测实测失效载荷(R²=0.955,斜率=1.021)。
  • 限制至临床10毫米区域,均质化有限元预测精确但倾向高估失效载荷(R²=0.952,斜率=0.780)。

关键数值与推荐

  • 20毫米节段微观有限元预测与实测失效载荷:R²=0.969,斜率=1.035。
  • 20毫米节段均质化有限元预测与实测失效载荷:R²=0.966,斜率=0.890。
  • 临床10毫米区域微观有限元预测与实测失效载荷:R²=0.955,斜率=1.021。
  • 临床10毫米区域均质化有限元预测与实测失效载荷:R²=0.952,斜率=0.780。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: This study developed a well-standardized and reproducible approach for micro-finite element (mFE) and homogenized-FE (hFE) analyses that can accurately predict the distal radius failure load using either mFE or hFE models when using the approaches and parameters developed in this study. INTRODUCTION: Micro-FE analyses based on high-resolution peripheral quantitative CT (HR-pQCT) images are frequently used to predict distal radius failure load. With the introduction of a second-generation HR-pQCT device, however, the default modelling approach no longer provides accurate results. The aim of this study was to develop a well-standardized and reproducible approach for mFE and hFE analyses that can provide precise and accurate results for distal radius failure load predictions based on second-generation HR-pQCT images. METHODS: Second-generation HR-pQCT was used to scan the distal 20-mm section of 22 cadaver radii. The sections were excised and mechanically tested afterwards. For these sections, mFE and hFE models were made that were used to identify required material parameters by comparing predicted and measured results. Using these parameters, the models were cropped to represent the 10-mm region recommended for clinical studies to test their performance for failure load prediction. RESULTS: After identification of material parameters, the measured failure load of the 20-mm segments was in good agreement with the results of mFE models (R2 = 0.969, slope = 1.035) and hFE models (R2 = 0.966, slope = 0.890). When the models were restricted to the clinical region, mFE still accurately predicted the measured failure load (R2 = 0.955, slope = 1.021), while hFE predictions were precise but tended to overpredict the failure load (R2 = 0.952, slope = 0.780). CONCLUSIONS: It was concluded that it is possible to accurately predict the distal radius failure load using either mFE or hFE models when using the approaches and parameters developed in this study.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Arias-Moreno AJ, Hosseini HS, Bevers M, et al. Validation of distal radius failure load predictions by homogenized- and micro-finite element analyses based on second-generation high-resolution peripheral quantitative CT images. Osteoporos Int. 2019. PMID: 30997546. doi:10.1007/s00198-019-04935-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。