恢复正常对称性?前交叉韧带重建术后9个月跳跃与变向测试中生物力学变量仍比正常更不对称
该对照实验室研究对比156例男性前交叉韧带重建(ACLR)术后9个月患者与62名健康参与者,在双腿落地跳、单腿落地跳、单腿跳远及计划与非计划变向任务中,ACLR组在全部跳跃与变向测试中生物力学变量不对称程度更大,单腿落地跳表现不对称效应量为0.94,作者认为提示康复不足。
要点
- ACLR术后9个月患者在全部跳跃与变向测试中生物力学变量不对称程度大于健康参与者。
- 组间差异多数位于矢状面和额状面,跳跃测试差异多于变向测试。
- 单腿落地跳表现不对称效应量为0.94,两项变向测试均为0.4,单腿跳远无差异。
核心结论
- ACLR术后9个月患者与健康参与者相比,在全部测试中生物力学变量不对称程度更大,作者认为提示康复不足。
研究设计与样本
- 对照实验室研究,纳入156例术后9个月男性患者与62名健康参与者,进行三维动作捕捉与分析。
- 测试任务包括双腿落地跳、单腿落地跳、单腿跳远以及计划与非计划变向。
- 采用肢体间均方根差计算各变量不对称程度,并使用统计参数映射识别组间不对称程度差异。
主要发现
- ACLR组在全部跳跃与变向测试中生物力学变量不对称程度均大于健康参与者。
- 组间差异多数位于矢状面和额状面,跳跃测试的差异多于变向测试。
- 单腿落地跳表现不对称组间差异效应量为0.94,两项变向测试均为0.4,单腿跳远无差异。
临床怎么用
- 作者指出,评估ACLR术后康复状态时应同时纳入生物力学变量与表现变量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: After anterior cruciate ligament reconstruction (ACLR), athletes have demonstrated performance asymmetries as compared with healthy cohorts, but little research has investigated if biomechanical asymmetries are also different during jump and change-of-direction (CoD) tasks between groups. PURPOSE: To identify if differences in magnitude of asymmetry of biomechanical and performance variables exist between these groups. STUDY DESIGN: Controlled laboratory study. METHODS: Analysis was conducted between 156 male patients 9 months after surgery and 62 healthy participants. Three-dimensional motion capture and analysis were carried out on a double-legged drop jump, a single-legged drop jump, a single-legged hop for distance, and planned and unplanned CoD. Asymmetry between limbs was calculated for each variable with root mean square difference between limbs. Statistical parametric mapping was used to identify the between-group differences in magnitude of asymmetry of performance and biomechanical variables. RESULTS: There were differences in asymmetry of biomechanical variables across all jump and CoD tests, with greater asymmetries in the ACLR group. The majority of differences between groups were in the sagittal and frontal planes, with more differences found in the jump than CoD tests. The single-legged drop jump demonstrated large differences in performance asymmetry (effect size, 0.94) with small differences for both CoD tests (0.4) and none for the single-legged hop for distance. CONCLUSION: This study demonstrated greater asymmetry of biomechanical variables 9 months after ACLR as compared with healthy participants across all tests, suggesting insufficient rehabilitation. CLINICAL RELEVANCE: This study highlights the importance of including biomechanical as well as performance variables when assessing rehabilitation status after ACLR. REGISTRATION: NCT02771548 ( ClinicalTrials.gov identifier).
引用
- King E, Richter C, Franklyn-Miller A, et al. Back to Normal Symmetry? Biomechanical Variables Remain More Asymmetrical Than Normal During Jump and Change-of-Direction Testing 9 Months After Anterior Cruciate Ligament Reconstruction. Am J Sports Med. 2019. PMID: 30943079. doi:10.1177/0363546519830656
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。