文献速递关节外科创伤骨科

应用带髓内杆的静态间隔物治疗伴严重骨缺损的慢性感染性全膝关节置换术后假体周围感染

Management of Chronically Infected Total Knee Arthroplasty With Severe Bone Loss Using Static Spacers With Intramedullary Rods.
PubMed 文献 · J Arthroplasty · 2019-03-29

本研究回顾了97例伴广泛骨缺损的慢性感染性全膝关节置换术后假体周围感染患者,均采用抗生素骨水泥静态间隔物联合髓内杆治疗,平均间隔物在位时间为9周(范围6-24周),再植入后平均随访41个月(范围27-56个月)。采用改良Delphi共识标准定义治疗成功,22例(23%)治疗失败,间隔物杆超声培养仅2例(2%)阳性且均未失败,结论认为该方案安全有效。

要点

  • 97例慢性感染性全膝关节置换术后假体周围感染伴广泛骨缺损患者采用抗生素骨水泥静态间隔物联合髓内杆治疗,22例(23%)治疗失败。
  • 间隔物杆超声培养阳性仅2例(2%),且这2例均未治疗失败。
  • 再感染患者中多数(9例)为不同微生物所致,仅3例为相同微生物再感染。

核心结论

  • 采用髓内杆的两阶段翻修术是治疗伴严重骨缺损的慢性感染性全膝关节置换术后假体周围感染的安全有效方法。
  • 大多数再感染与初始感染相比培养出不同微生物。
  • 宿主和肢体状态受损的患者可能需要长期抗生素抑制治疗。

研究设计与样本

  • 回顾性研究,纳入97例伴广泛骨缺损的感染性全膝关节置换术后假体周围感染患者,均接受负载抗生素骨水泥间隔物联合髓内杆治疗。
  • 间隔物原位平均间隔时间为9周(范围6-24周),再植入后平均随访41个月(范围27-56个月)。
  • 治疗成功采用改良Delphi共识标准定义。
  • 术中培养及间隔物杆超声培养进行分析。

主要发现

  • 22例(23%)治疗失败,包括3例相同微生物再感染、9例不同微生物再感染、9例需更换间隔物、1例术后早期死亡。
  • 间隔物杆超声培养阳性2例(2%),这2例均未治疗失败。
  • 再感染患者的宿主和肢体状态显著更差。
  • 末次随访时所有患者均保有全膝关节假体,2例接受长期抗生素抑制治疗。

关键数值与推荐

  • 治疗成功采用改良Delphi共识标准定义。
  • 间隔物杆超声培养阳性2例(2%)。
  • 治疗失败22例(23%)。

临床怎么用

  • 对于伴严重骨缺损的慢性感染性全膝关节置换术后假体周围感染,采用带髓内杆的静态抗生素间隔物进行两阶段翻修是安全有效的治疗选择。
  • 宿主和肢体状态受损的患者可能需接受长期抗生素抑制治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Two-stage revision with static antibiotic spacers is the preferred treatment for chronically infected total knee arthroplasty (TKA) associated with severe bone loss. Intramedullary rods to reinforce static spacers have been described. On those, however, bacterial colonization may occur and hamper infection control. This study reports the microbiological findings on the spacer rods and the treatment outcome among these patients. METHODS: We reviewed 97 infected TKA with extensive bone loss treated with antibiotic-loaded cement spacers reinforced with intramedullary rods. Mean interim period with the spacer in situ was 9 weeks (range: 6-24 weeks). Intraoperative cultures and sonicated spacer rods were analyzed. Mean follow-up after TKA reimplantation was 41 months (range: 27-56 months). Treatment success was defined using the modified Delphi consensus criteria. RESULTS: Twenty-two patients (23%) had treatment failure, including 3 reinfections caused by the same organism, 9 reinfections caused by a different organism, 9 patients required interim spacer exchange, and 1 patient died in the early postoperative course. Sonication cultures of the spacer rods were positive in 2 cases (2%), and none of them failed. Host and limb status was significantly worse in patients who sustained reinfection. At the latest follow-up, all patients had a TKA in place, and 2 patients received chronic antibiotic suppression. CONCLUSION: Two-stage revision with the use of intramedullary rods is a safe and efficient treatment for chronically infected TKA with severe bone loss. Most reinfections grew different organisms compared with initial infection. Compromised hosts and extremities may be subjected to chronic antibiotic suppression.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hipfl C, Winkler T, Janz V, et al. Management of Chronically Infected Total Knee Arthroplasty With Severe Bone Loss Using Static Spacers With Intramedullary Rods. J Arthroplasty. 2019. PMID: 31023514. doi:10.1016/j.arth.2019.03.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。