文献速递关节外科

血浆纤维蛋白原在假体周围关节感染诊断中的表现优于血浆D-二聚体:一项多中心回顾性研究

Plasma Fibrinogen Exhibits Better Performance Than Plasma D-Dimer in the Diagnosis of Periprosthetic Joint Infection: A Multicenter Retrospective Study.
PubMed 文献 · J Bone Joint Surg Am · 2019-01-01

该多中心回顾性研究纳入2016年1月至2017年12月共565例髋膝关节翻修病例,其中126例有凝血相关合并症并单独分析,剩余439例含76例假体周围关节感染(PJI)和363例非PJI患者。以国际共识会议(ICM)PJI标准定义感染,采用ROC曲线分析D-二聚体、血浆纤维蛋白原、红细胞沉降率(ESR)、C反应蛋白(CRP)及白细胞(WBC)计数的诊断价值,发现血浆纤维蛋白原AUC最高(0.852),D-二聚体AUC仅0.657。

要点

  • 血浆纤维蛋白原诊断PJI的AUC为0.852,高于CRP(0.810)和ESR(0.808)。
  • 血浆D-二聚体诊断PJI的AUC为0.657,仅略高于WBC计数的0.590。
  • 血浆纤维蛋白原最佳阈值为4.01 g/L,灵敏度0.763,特异度0.862。

核心结论

  • 血浆D-二聚体对PJI的诊断价值可能非常有限,而血浆纤维蛋白原作为另一凝血相关指标表现出有前景的诊断性能。
  • 血浆纤维蛋白原诊断PJI具有良好的灵敏度和特异度,其数值与CRP水平和ESR等经典标志物相似。

研究设计与样本

  • 多中心回顾性研究,纳入2016年1月至2017年12月共565例髋膝关节翻修病例,其中126例有凝血相关合并症并单独分析。
  • 剩余439例含76例PJI和363例非PJI患者,PJI定义基于国际共识会议(ICM)假体周围感染标准。
  • 采用受试者工作特征(ROC)曲线分析D-二聚体、血浆纤维蛋白原、ESR、CRP水平及WBC计数的诊断价值。

主要发现

  • 血浆纤维蛋白原的AUC最高,为0.852;CRP的AUC为0.810,ESR的AUC为0.808。
  • D-二聚体的AUC为0.657,为第二低值,仅略高于WBC计数的0.590。
  • 血浆D-二聚体最佳阈值为1.25 μg/mL,灵敏度、特异度、阳性预测值(PPV)和阴性预测值(NPV)分别为0.645、0.650、0.278和0.897。
  • 血浆纤维蛋白原最佳阈值为4.01 g/L,灵敏度、特异度、PPV和NPV分别为0.763、0.862、0.537和0.946。

关键数值与推荐

  • PJI定义基于国际共识会议(ICM)假体周围感染标准。
  • 血浆D-二聚体最佳阈值1.25 μg/mL,灵敏度0.645,特异度0.650,PPV 0.278,NPV 0.897。
  • 血浆纤维蛋白原最佳阈值4.01 g/L,灵敏度0.763,特异度0.862,PPV 0.537,NPV 0.946。
  • 证据等级:诊断Level III。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The search for potential markers for a timely and accurate diagnosis of periprosthetic joint infection (PJI) is ongoing. Previous studies have focused on inflammatory markers and have rarely examined coagulation-related indicators. The purpose of this study was to evaluate the values of plasma fibrinogen, D-dimer, and other blood markers for the diagnosis of PJI through a multicenter retrospective study. METHODS: A total of 565 revision total hip and knee arthroplasty cases were enrolled in this study from January 2016 through December 2017, 126 of which had coagulation-related comorbidities and were analyzed separately. The remaining 439 cases included 76 PJI and 363 non-PJI patients. The definition of PJI was based on the International Consensus Meeting (ICM) on Periprosthetic Infection criteria. The diagnostic values of D-dimer, plasma fibrinogen, the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and white blood-cell (WBC) count were analyzed using receiver operating characteristic (ROC) curves. RESULTS: ROC curves showed that plasma fibrinogen had the highest area under the curve (AUC), 0.852, followed by 2 classical markers, the CRP level and ESR, which had an AUC of 0.810 and 0.808, respectively. D-dimer had an AUC of 0.657, which was the second lowest value and only slightly higher than that of the WBC count, 0.590. The optimal threshold for plasma D-dimer was 1.25 μg/mL, with a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 0.645, 0.650, 0.278, and 0.897, respectively. The optimal threshold for plasma fibrinogen was 4.01 g/L, which showed good sensitivity, specificity, PPV, and NPV, with values of 0.763, 0.862, 0.537, and 0.946, respectively. CONCLUSIONS: Plasma D-dimer may have a very limited diagnostic value for PJI, while plasma fibrinogen, another coagulation-related indicator, exhibits promising performance. Plasma fibrinogen has good sensitivity and specificity for diagnosing PJI, with values similar to those of classical markers, including CRP level and ESR. LEVEL OF EVIDENCE: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Li R, Shao HY, Hao LB, et al. Plasma Fibrinogen Exhibits Better Performance Than Plasma D-Dimer in the Diagnosis of Periprosthetic Joint Infection: A Multicenter Retrospective Study. J Bone Joint Surg Am. 2019. PMID: 30946195. doi:10.2106/JBJS.18.00624

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。