术前骨扫描评估全膝关节翻修术中假体松动的价值
本研究回顾性分析96例全膝关节翻修术(rTKA)患者,比较术前骨扫描放射科报告(RR)与术者预测(SP)对假体松动的判断同术中所见(IF)的一致性。结果显示RR与IF正确率37%,SP正确率69%(P < .001);RR与IF的kappa仅0.23,SP与IF的kappa为0.57,RR与SP的kappa为0.36。
要点
- 骨扫描报告与术中假体松动所见一致性极低(kappa 0.23,95%CI 0.15-0.32)。
- 术者术前判断与术中假体松动所见一致性弱(kappa 0.57,95%CI 0.46-0.68)。
- 术者判断正确率69%,高于骨扫描报告的37%(P < .001)。
核心结论
- 在rTKA中,放射科医生对术前骨扫描的判读与术者基于临床和影像数据的术前判断在假体松动方面一致性弱。
- 两者均不能可靠准确预测rTKA术中所见,但术者术前判断与实际术中假体松动所见相关性更密切。
研究设计与样本
- 回顾性分析本机构数据库,纳入骨扫描后行rTKA的96例合格病例。
- 将放射科报告(RR)与术者预测(SP)按假体松动所有可能组合细分,并与术中所见(IF)比较。
- 计算RR与SP相对IF的正确百分比,并用kappa统计比较RR与SP之间的一致性水平。
主要发现
- 96例中,RR与IF正确相关35例(37%),SP正确66例(69%),术者术前判读正确频率更高(P < .001)。
- RR与IF的kappa为0.23(95%CI 0.15-0.32),提示一致性极低。
- SP与IF的kappa为0.57(95%CI 0.46-0.68),提示一致性弱。
- RR与SP之间的kappa为0.36(95%CI 0.27-0.45),同样提示一致性极低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Bone scintigraphy (BS) is frequently ordered to investigate cause of failure following total knee arthroplasty (TKA). Its correlation of component loosening with intraoperative findings (IFs) at the time of revision TKA (rTKA) has not been well studied. This study investigated correlations between the preoperatively obtained radiologist report (RR) of BS, preoperatively documented surgeon prediction (SP) of component loosening, and operative reports documenting IFs. METHODS: Our institutional database was retrospectively reviewed for all rTKA done after BS and revealed 96 eligible cases. The RR and SP cohorts were subdivided into all potential combinations of component loosening and were then compared with each other as well as IF. In addition to calculating the percentage correct of RR and SP compared with IF, the levels of agreement between RR and SP were compared using the kappa statistic. RESULTS: Of the 96 cases, the RR correctly correlated with IF in 35 cases (37%), whereas the SP was correct in 66 cases (69%), indicating the preoperative interpretation of the surgeon regarding component loosening at rTKA was correct more frequently (P < .001). The kappa statistic between RR and IF was only 0.23 (95% confidence interval [CI] = 0.15-0.32), indicating minimal agreement. The kappa statistic between SP and IF was 0.57 (95% = CI 0.46-0.68), indicating weak agreement. Furthermore, the kappa statistic between RR and SP was 0.36 (95% CI = 0.27-0.45), also indicating minimal agreement. CONCLUSIONS: In rTKA, there is weak agreement regarding component loosening between a radiologist's opinion of a preoperatively obtained bone scan and the surgeon's preoperative interpretation of clinical and radiographic data. While neither reliably accurately predicts what is found at the time of rTKA, the surgeon's preoperative interpretation is more closely correlated with actual IFs of component loosening.
引用
- Holst DC, Angerame MR, Dennis DA, et al. What Is the Value of Component Loosening Assessment of a Preoperatively Obtained Bone Scan Prior to Revision Total Knee Arthroplasty? J Arthroplasty. 2019. PMID: 31010774. doi:10.1016/j.arth.2019.02.065
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。