文献速递关节外科

氧化锆股骨头在全髋关节置换术中是否优于其他轴承类型?一项系统综述与荟萃分析

Is Oxidized Zirconium Femoral Head Superior to Other Bearing Types in Total Hip Arthroplasty? A Systematic Review and Meta-Analysis.
PubMed 文献 · J Arthroplasty · 2019-04-02

该系统综述与荟萃分析检索MEDLINE/PubMed和Cochrane系统综述数据库,比较氧化锆(OxZi)股骨头与其他轴承类型在全髋关节置换术中的聚乙烯磨损、生存率和临床结局;结果显示OxZi与钴铬(CoCr)股骨头的聚乙烯磨损率无显著差异(率比0.836,95%CI 0.362-1.928,P=0.674),生存率均极佳;作者不推荐在初次全髋关节置换术中常规使用OxZi股骨头。

要点

  • OxZi与CoCr股骨头的聚乙烯磨损率无显著差异(率比0.836,95%CI 0.362-1.928,P=0.674)。
  • 所有比较OxZi与CoCr股骨头生存率的研究均显示两种植入物生存率极佳。
  • 作者不推荐在初次全髋关节置换术中常规使用OxZi股骨头。

核心结论

  • 与CoCr股骨头相比,OxZi股骨头在全髋关节置换术患者中未导致更低的聚乙烯磨损率或更高的生存率。
  • 基于这些结果并考虑到这些植入物更高的成本,作者不推荐在初次全髋关节置换术中常规使用OxZi股骨头。

研究设计与样本

  • 系统综述与荟萃分析,由两名评价者独立按照PRISMA指南检索MEDLINE/PubMed数据库和Cochrane系统综述数据库。
  • 检索词为「oxidized」AND「zirconium」AND「total」AND「hip」AND「arthroplasty」以及「oxinium」AND「total」AND「hip」AND「arthroplasty」。
  • 主要结局指标为轴承表面的生存率以及聚乙烯磨损。
  • 证据等级为治疗性研究I-III级的系统综述与荟萃分析。

主要发现

  • 报告平均聚乙烯磨损率的研究中绝大多数(85.7%)显示OxZi与CoCr股骨头之间无任何显著差异(率比0.836,95%CI 0.362-1.928,P=0.674)。
  • 所有比较OxZi与CoCr股骨头生存率的研究均显示两种植入物生存率几乎极佳。

关键数值与推荐

  • OxZi与CoCr股骨头的聚乙烯磨损率比较:率比0.836(95%CI 0.362-1.928,P=0.674),无显著差异。
  • 报告平均聚乙烯磨损率的研究中85.7%显示OxZi与CoCr股骨头之间无显著差异。

临床怎么用

  • 作者基于结果并考虑植入物更高成本,不推荐在初次全髋关节置换术中常规使用OxZi股骨头。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Oxidized zirconium (OxZi) is a relatively new type of material that combines the strength of a metal with the surface/wears properties of a ceramic. Our aim was to investigate whether OxZi femoral heads lead to lower polyethylene wear, higher survival rate, and better clinical outcomes than the other bearing types in patients treated with total hip arthroplasty (THA). METHODS: Two reviewers independently conducted a systematic search according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses using the MEDLINE/PubMed database and the Cochrane Database of Systematic Reviews. These databases were queried with the terms: a. "oxidized" AND "zirconium" AND "total" AND "hip" AND "arthroplasty"; b. "oxinium" AND "total" AND "hip" AND "arthroplasty". The primary outcome measures were the survival rate of the bearing surfaces as well as the polyethylene wear. RESULTS: The vast majority (85.7%) of the studies, which reported the mean polyethylene wear rate, showed that there was not any significant difference between OxZi and cobalt-chrome (CoCr) femoral heads (rate ratio: 0.836; 95% confidence interval: 0.362-1.928; P = .674). All studies comparing the survival rate of OxZi and CoCr femoral heads illustrated almost excellent survivorship with both implants. CONCLUSION: OxZi femoral heads did not lead to lower polyethylene wear rate or higher survival rate, when compared with CoCr femoral heads in patients treated with THA. On the basis of these results and taking into account the higher cost of these implants, we would not recommend the routine use of OxZi femoral heads in primary THAs. LEVEL OF EVIDENCE: Systematic review and meta-analysis of therapeutic studies I-III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Malahias MA, Atrey A, Gu A, et al. Is Oxidized Zirconium Femoral Head Superior to Other Bearing Types in Total Hip Arthroplasty? A Systematic Review and Meta-Analysis. J Arthroplasty. 2019. PMID: 31010775. doi:10.1016/j.arth.2019.03.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。