文献速递关节外科

全膝关节翻修术中忽略髌骨:髌骨假体保留至少5年随访

Ignore the Patella in Revision Total Knee Surgery: A Minimum 5-Year Follow-Up With Patella Component Retention.
PubMed 文献 · J Arthroplasty · 2019-03-14

本研究纳入147例(137例患者)无菌性全膝关节翻修术,术中均未翻修髌骨,平均随访至少5年(范围5至12年)。末次随访时所有髌骨均无再手术、无失败风险,尽管术中见30例髌骨假体磨损及5例髌骨与股骨假体形态不匹配。作者结论为中期随访中未翻修的髌骨无后续失败。

要点

  • 无菌性翻修时保留髌骨假体,中期随访无髌骨再手术或失败。
  • 术中可见30例髌骨聚乙烯磨损及5例髌骨-股骨假体形态不匹配。
  • 末次随访6膝髌骨外侧倾斜超过10°,但无一例半脱位。

核心结论

  • 在全膝关节翻修术未翻修髌骨的中期随访中,未发现髌骨后续失败,尽管存在轻度髌骨聚乙烯磨损和部分膝关节形态不匹配。

研究设计与样本

  • 研究为147例连续无菌性全膝关节翻修术(137例患者),平均年龄70.1±9.3岁,平均体重指数31.0±5.4 kg/m2,随访至少5年(范围5至12年)。
  • 末次随访时13例患者死亡、2例失访,余122例患者、130膝可供评估;从初次手术到翻修术平均时间9.2±5.5年。
  • 50膝翻修两个组件、11膝仅翻修股骨、12膝仅翻修胫骨、57膝为单纯聚乙烯翻修;术中见5例髌骨与股骨假体形态不匹配、30例髌骨假体磨损。

主要发现

  • 末次随访时所有髌骨均无再手术,无一例处于失败风险中。
  • 6膝存在超过10°的髌骨外侧倾斜,但无一例半脱位。
  • 末次随访膝关节协会评分平均85±17.2分。

关键数值与推荐

  • 末次随访膝关节协会评分平均85±17.2分。
  • 6膝髌骨外侧倾斜超过10°,无半脱位。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 证据等级为III级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In the setting of aseptic revision, a common question is: what should be done with the previously resurfaced patella? We report on a series of aseptic revision total knee arthroplasties (RTKA) where one or both components were revised and the patella was not. METHODS: The study group was 147 consecutive RTKA in 137 patients with a mean age of 70.1 ± 9.3 years where the patella was not revised. The average body mass index was 31.0 ± 5.4 kg/m2. Follow-up was a minimum of 5 years (range, 5 to 12 years). At final follow-up, 13 patients died and 2 patients were lost to follow-up leaving 122 patients and 130 knees available for review. Mean time from primary surgery to RTKA was 9.2 ± 5.5 years. Both components were revised in 50 knees, the femur only in 11 knees, the tibia only in 12 knees, and 57 had an isolated polyethylene revision. We found 5 patients with a mismatch between the patella and femoral components and 30 cases with patella component wear identified intraoperatively. RESULTS: At final follow-up, there were no reoperations on any patella and none were at risk of failure. There were 6 knees with a lateral patella tilt beyond 10°, but none were subluxed. Knee Society Scores averaged 85 ± 17.2 points at final follow-up. CONCLUSION: At midterm follow-up in this group of RTKA where the patella was not revised, we identified no subsequent failures of the patella. This is despite the presence of mild patella polyethylene wear and mismatched shapes in several knees. LEVEL OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Shield WP, Greenwell PH, Chapman DM, et al. Ignore the Patella in Revision Total Knee Surgery: A Minimum 5-Year Follow-Up With Patella Component Retention. J Arthroplasty. 2019. PMID: 30979670. doi:10.1016/j.arth.2019.03.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。