文献速递关节外科创伤骨科

α-防御素与白细胞酯酶试验在肩关节假体周围感染中的诊断准确性如何

What Is the Diagnostic Accuracy of Alpha-Defensin and Leukocyte Esterase Test in Periprosthetic Shoulder Infection?
PubMed 文献 · Clin Orthop Relat Res · 2019-01-01

单中心纳入2015年7月至2018年2月因疼痛性全肩关节置换术后行关节穿刺的105例患者,按肌肉骨骼感染学会标准分为感染组24例与无菌组81例,评估滑液α-防御素酶联免疫吸附试验、白细胞酯酶及血清C反应蛋白的诊断准确性;α-防御素总体准确率91%、敏感度75%、特异度96%,白细胞酯酶总体准确率76%、敏感度50%、特异度87%,作者认为两者可作为疼痛性全肩关节置换患者的辅助诊断工具。

要点

  • α-防御素酶联免疫吸附试验诊断肩关节假体周围感染总体准确率91%,敏感度75%、特异度96%。
  • 白细胞酯酶总体准确率76%,敏感度50%、特异度87%,敏感度低于既往膝关节或髋关节置换报告。
  • 15例(63%)感染患者培养出痤疮皮肤杆菌(Cutibacterium acnes,原痤疮丙酸杆菌)。

核心结论

  • α-防御素酶联免疫吸附试验与白细胞酯酶试验检测肩关节假体周围感染的敏感度低于既往全膝关节置换或全髋关节置换的报告结果。
  • 关节液质量与量少是诊断的困难环节,痤疮皮肤杆菌(原痤疮丙酸杆菌)是最常见的感染病原。
  • 针对低度感染,α-防御素在诊断假体周围感染时显示出不受病原毒力影响的优势。
  • 作者认为α-防御素与白细胞酯酶试验可作为疼痛性全肩关节置换患者的辅助诊断工具。
  • 作者提出需进一步前瞻性研究以改进诊断并确认结果。

研究设计与样本

  • 单中心研究,纳入2015年7月至2018年2月因疼痛性全肩关节置换术后行关节穿刺以验证或排除假体周围感染的患者。
  • 共121例患者行穿刺,排除16例,最终分析105例,平均年龄68岁(±12岁)。
  • 按肌肉骨骼感染学会标准分为感染组24例与无菌组81例。
  • 滑液行微生物培养、α-防御素免疫测定与白细胞酯酶检测,并计算各试验的敏感度、特异度、阳性预测值与阴性预测值。
  • 证据等级为III级,诊断性研究。

主要发现

  • α-防御素总体准确率91%(95%CI 84.4-96),敏感度75%(95%CI 53-90),特异度96%(95%CI 90-99),阴性预测值93%(95%CI 85-97),阳性预测值86%(95%CI 64-97)。
  • 白细胞酯酶总体准确率76%(95%CI 61-88),敏感度50%(95%CI 21-79),特异度87%(95%CI 69-96),阳性预测值60%(95%CI 26-88),阴性预测值81%(95%CI 64-93)。
  • 微生物学评估包括混合感染,显示15例(63%)为痤疮皮肤杆菌(原痤疮丙酸杆菌)。

关键数值与推荐

  • 采用肌肉骨骼感染学会标准判定全肩关节置换术后患者为无菌或感染。
  • α-防御素酶联免疫吸附试验:总体准确率91%(95%CI 84.4-96),敏感度75%(95%CI 53-90),特异度96%(95%CI 90-99)。
  • 白细胞酯酶试验:总体准确率76%(95%CI 61-88),敏感度50%(95%CI 21-79),特异度87%(95%CI 69-96)。

临床怎么用

  • 作者认为α-防御素与白细胞酯酶试验可作为疼痛性全肩关节置换患者的辅助诊断工具。
  • 作者提出需进一步前瞻性研究以改进诊断并确认结果。

局限性

  • 作者指出α-防御素酶联免疫吸附试验与白细胞酯酶试验检测肩关节假体周围感染的敏感度低于既往全膝关节置换或全髋关节置换的报告结果。
  • 关节液质量与量少是诊断的困难环节。
  • 作者提出需进一步前瞻性研究以改进诊断并确认结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnosis of periprosthetic joint infection (PJI) after total shoulder arthroplasty (TSA) is challenging, especially in patients with Cutibacterium (formerly Propionibacterium) acnes infection. Despite the increasing number of patients with PJI of the shoulder, there are still no robust data regarding diagnostic tests in detecting shoulder PJI. QUESTIONS/PURPOSES: (1) What are the sensitivity, specificity, and negative- and positive-predictive values for the alpha-defensin enzyme-linked immunosorbent assay test in detecting PJI after TSA? (2) What are the diagnostic accuracies in detecting shoulder PJI for synovial alpha-defensin, leukocyte esterase Test, and serum C-reactive protein (CRP)? METHODS: All patients with painful TSA, who underwent joint aspiration to validate or exclude a PJI, between July 2015 and February 2018 were enrolled in this single-center study. Further indications for aspiration were as follows: planned revision arthroplasty, early loosening and clinical signs of infections, especially serum CRP elevation. A total of 121 patients were aspirated to exclude or verify a PJI, and 16 patients were excluded. In all, 105 patients with a mean age of 68 years (± 12 years) were included for analysis. Patients who underwent TSA were considered aseptic or septic according to the Musculoskeletal Infection Society criteria. Twenty-four patients had a PJI, and the remaining 81 patients were in the aseptic group. The microbiologic evaluation including polymicrobial infection showed C. (formerly P.) acnes in 15 patients (63%). Synovial fluid was then analyzed using microbiology cultures, alpha-defensin immunoassay, and leukocyte esterase. The specificity, sensitivity, and positive-predictive and negative-predictive values were calculated for each test. RESULTS: The overall accuracy for alpha-defensin was 91% (95% confidence interval [CI], 84.4-96); sensitivity was 75% (95% CI, 53-90), specificity was 96% (95% CI, 90-99), negative predictive value was 93% (95% CI, 85-97), and positive predictive value was 86% (95% CI, 64-97). In contrast, the overall accuracy for leukocyte esterase was 76% (95% CI, 61-88), sensitivity was 50% (95% CI, 21-79), specificity was 87% (95% CI, 69-96), positive predictive value 60% (95% CI, 26-88) and negative predictive value was 81% (95% CI, 64-93). CONCLUSIONS: Summarizing the study results, the alpha-defensin ELISA and leukocyte esterase tests had less sensitivity in detecting shoulder PJI than previously reported TKA or THA results. The quality and low amount of joint fluid is the difficult part of the diagnostic. C. (formerly P.) acnes was the most common cause of PJI. Focusing on low-grade infections, alpha-defensin has shown its advantages in diagnosing PJI regardless pathogen virulence. Since the diagnostic of a PJI is always a synopsis of findings, the alpha-defensin and leukocyte esterase test can be used as adjunct diagnostic tool in patients with painful TSA. We propose further prospective studies to improve the diagnostic and confirm the results. LEVEL OF EVIDENCE: Level III, diagnostic study.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Unter Ecker N, Koniker A, Gehrke T, et al. What Is the Diagnostic Accuracy of Alpha-Defensin and Leukocyte Esterase Test in Periprosthetic Shoulder Infection? Clin Orthop Relat Res. 2019. PMID: 30998585. doi:10.1097/CORR.0000000000000762

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。