组件位置是否影响机器人辅助单间室膝关节置换术的短期临床结局?
这项多中心观察性研究纳入2013至2016年间两家中心的363例患者(395膝)接受机器人辅助单间室膝关节置换术,分析术中组件位置与软组织平衡同短期临床结局的关联。中位随访30.0个月时评估334例内侧单间室膝关节置换术,未发现所测参数与整体KOOS结局相关,但特定KOOS亚量表与术中机器人数据、FJS-12与股骨组件矢状面对线之间存在相关性。作者认为尽管相关性有限,术者仍应考虑3D组件位置和软组织平衡信息以改善患者满意度。
要点
- 所测参数均与整体KOOS结局无关联。
- 特定KOOS亚量表与术中机器人数据存在相关性。
- FJS-12与股骨组件矢状面对线存在相关性。
核心结论
- 尽管术中机器人数据与整体临床结局之间相关性很小,但术者应考虑3D组件位置和软组织平衡信息以改善患者满意度。
- 可重复且精确的组件放置已被证实对满意的临床结局至关重要。
研究设计与样本
- 多中心观察性研究,2013年至2016年间两家中心共363例患者(395膝)接受机器人辅助单间室膝关节置换术。
- 术前和术后对患者进行KOOS和FJS-12评分,KOOS/FJS-12大于或等于80分者分层为「好」,否则为「坏」。
- 收集并分类术中植入后机器人数据(相对于基于CT的组件放置),记录术后并发症。
- 排除和失访后,334例内侧机器人辅助单间室膝关节置换术在平均随访30.0个月(8.0至54.9)时被评估。
主要发现
- 所测参数均与整体KOOS结局无关联。
- 特定KOOS亚量表与术中植入后机器人数据之间存在相关性。
- FJS-12与股骨组件矢状面对线之间存在相关性。
- 3例单间室膝关节置换术接受翻修,两年生存率为99.0%(95%CI 97.9至100.0)。
临床怎么用
- 作者认为,尽管术中机器人数据与整体临床结局之间相关性很小,术者应考虑3D组件位置和软组织平衡信息以改善患者满意度。
- 作者指出,可重复且精确的组件放置已被证实对满意的临床结局至关重要。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The purpose of this multicentre observational study was to investigate the association between intraoperative component positioning and soft-tissue balancing on short-term clinical outcomes in patients undergoing robotic-arm assisted unicompartmental knee arthroplasty (UKA). PATIENTS AND METHODS: Between 2013 and 2016, 363 patients (395 knees) underwent robotic-arm assisted UKAs at two centres. Pre- and postoperatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS) and Forgotten Joint Score-12 (FJS-12). Results were stratified as "good" and "bad" if KOOS/FJS-12 were more than or equal to 80. Intraoperative, post-implantation robotic data relative to CT-based components placement were collected and classified. Postoperative complications were recorded. RESULTS: Following exclusions and losses to follow-up, 334 medial robotic-arm assisted UKAs were assessed at a mean follow-up of 30.0 months (8.0 to 54.9). None of the measured parameters were associated with overall KOOS outcome. Correlations were described between specific KOOS subscales and intraoperative, post-implantation robotic data, and between FJS-12 and femoral component sagittal alignment. Three UKAs were revised, resulting in 99.0% survival at two years (95% confidence interval (CI) 97.9 to 100.0). CONCLUSION: Although little correlation was found between intraoperative robotic data and overall clinical outcome, surgeons should consider information regarding 3D component placement and soft-tissue balancing to improve patient satisfaction. Reproducible and precise placement of components has been confirmed as essential for satisfactory clinical outcome. Cite this article: Bone Joint J 2019;101-B:435-442.
引用
- Zambianchi F, Franceschi G, Rivi E, et al. Does component placement affect short-term clinical outcome in robotic-arm assisted unicompartmental knee arthroplasty? Bone Joint J. 2019. PMID: 30929494. doi:10.1302/0301-620X.101B4.BJJ-2018-0753.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。