本研究纳入2015年6月至2017年12月间行翻修全髋关节置换术的119例患者,比较术中白细胞酯酶(LE)检测与冰冻切片(FS)组织学诊断假体周围感染(PJI)的效能。LE的敏感性和特异性分别为100%和93.8%,FS分别为78.3%和96.9%;LE结果回报时间更短,作者认为LE可作为FS的有价值替代并已常规用于术中诊断PJI。
要点
- LE检测诊断PJI的敏感性为100%、特异性为93.8%,PPV为79.3%、NPV为100%。
- FS组织学诊断PJI的敏感性为78.3%、特异性为96.9%,PPV为85.7%、NPV为94.9%。
- LE结果回报平均20.1分钟(sd 4.4),短于FS的27.2分钟(sd 6.9)。
核心结论
- 与FS组织学相比,LE检测敏感性更高,特异性和诊断准确性相似,结果回报更快、操作简便且成本低,作者认为LE是FS的有价值替代,并已常规用于PJI术中诊断。
研究设计与样本
- 纳入2015年6月至2017年12月间行翻修全髋关节置换术的119例患者,其中男56例、女63例,平均年龄66.2岁(范围27至88岁)。
- 切开关节囊前采集滑液,用酶比色条行LE检测;取5至6份样本行苏木精-伊红染色FS组织学检查。
- FS以5个高倍视野中至少发现5个多形核白细胞为提示感染。
主要发现
- LE检测的敏感性和特异性分别为100%和93.8%,阳性预测值和阴性预测值分别为79.3%和100%。
- FS组织学的敏感性和特异性分别为78.3%和96.9%,阳性预测值和阴性预测值分别为85.7%和94.9%。
- LE从采样到获知结果的平均时间为20.1分钟(sd 4.4),FS为27.2分钟(sd 6.9)。
关键数值与推荐
- FS组织学以5个高倍视野中至少5个多形核白细胞为提示感染的标准。
- LE检测的敏感性100%、特异性93.8%、PPV 79.3%、NPV 100%。
- FS组织学的敏感性78.3%、特异性96.9%、PPV 85.7%、NPV 94.9%。
临床怎么用
- 作者认为LE检测是FS组织学的有价值替代,并已在所在机构常规用于PJI的术中诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection. PATIENTS AND METHODS: A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields. RESULTS: The sensitivity and specificity of the LE assay were 100% and 93.8%, respectively; the positive (PPV) and the negative (NPV) predictive values were 79.3% and 100%, respectively. The mean time between the collection of the sample and the result being known was 20.1 minutes (sd 4.4). The sensitivity and specificity of FS histology were 78.3% and 96.9%, respectively; the PPV and the NPV were 85.7% and 94.9%, respectively. The mean time between the collection of the sample and the result being known was 27.2 minutes (sd 6.9). CONCLUSION: The sensitivity of LE assay was higher, with similar specificity and diagnostic accuracy, compared with FS histology. The faster turnaround time, its ease of use, and low costs make LE assay a valuable alternative to FS histology. We now use it routinely for the intraoperative diagnosis of PJI. Cite this article: Bone Joint J 2019;101-B:372-377.
引用
- Zagra L, Villa F, Cappelletti L, et al. Can leucocyte esterase replace frozen sections in the intraoperative diagnosis of prosthetic hip infection? Bone Joint J. 2019. PMID: 30929495. doi:10.1302/0301-620X.101B4.BJJ-2018-0752.R1