PubMed 文献 · J Arthroplasty · 2019-03-19

本研究纳入487例(576膝)接受Oxford活动平台单髁膝关节置换术且至少随访5年的患者,按UCLA评分分为低活动组(≤6)和高活动组(≥7)。高活动组翻修率为6.2%,低活动组为8.4%(P=0.43);平均9年随访时假体生存率分别为94.0%和92.1%(P=0.6085)。结论认为高活动患者术后翻修风险未增加。

要点

  • 高活动组翻修率6.2%,低活动组8.4%,差异无统计学意义(P=0.43)。
  • 平均9年随访假体生存率:高活动组94.0%,低活动组92.1%(P=0.6085)。
  • 高活动组术后Knee Society评分和疼痛改善显著高于低活动组。

核心结论

  • 高活动患者接受Oxford活动平台单髁膝关节置换术后,在至少5年随访中翻修风险未增加。

研究设计与样本

  • 回顾性识别487例(576膝)接受Oxford活动平台单髁膝关节置换术且至少随访5年的患者,按UCLA评分分为低活动组(≤6)和高活动组(≥7),评估术前术后活动度、Knee Society评分、并发症和再手术。

主要发现

  • 平均随访9年(范围4至13.1年)。
  • 高活动组男性显著更多、更年轻,术前Knee Society临床评分和功能评分更高。
  • 高活动组术后Knee Society评分和疼痛改善显著更高。
  • 翻修率:低活动组8.4% vs 高活动组6.2%(P=0.43)。
  • 平均9年随访假体生存率:高活动组94.0% vs 低活动组92.1%(P=0.6085)。

关键数值与推荐

  • 低活动组定义为University of California Los Angeles评分≤6,高活动组定义为≥7。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients are often cautioned against a high level of activity after knee arthroplasty. The purpose of this study was to report on implant survivorship and outcomes of high-activity patients compared with low-activity patients after unicondylar knee arthroplasty (UKA). METHODS: We identified 487 patients (576 knees) who underwent UKA with the Oxford mobile bearing knee (Zimmer Biomet, Warsaw, IN) with a 5-year minimum follow-up. Patients were divided into 2 groups: low activity (LA) (University of California Los Angeles ≤6) and high activity (HA) (University of California Los Angeles ≥7). Preoperative and postoperative range of motion, Knee Society scores, complications, and reoperations were evaluated. RESULTS: Mean follow-up was 9 years (range, 4 to 13.1). The HA group had significantly more male patients, were younger, and had higher knee society clinical scores and knee society functional scores preoperatively. The HA group had significantly higher improvements in Knee Society scores and pain postoperatively. Revisions were performed in 8.4% of the LA group and 6.2% of the HA group (P = .43). At our mean of 9-year follow-up, there was 94.0% survival for the HA group and 92.1% for the LA group (P = .6085). CONCLUSIONS: Highly active patients had no increased risk of revision after UKA with the Oxford mobile bearing knee at 5-year minimum follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。