文献速递关节外科

非模块化股骨柄可作为翻修全髋关节置换术中模块化股骨柄的可行替代方案

Nonmodular Stems Are a Viable Alternative to Modular Stems in Revision Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2019-03-19

本研究回顾2013年1月1日至2017年9月30日间146例翻修全髋关节置换术(103例模块化柄、43例非模块化柄),平均随访29个月。非模块化柄成本显著低于模块化柄(模块化柄成本高120.8%,P<.001),手术时间更长(193分钟 vs 163分钟,P=.029),但住院时间、再翻修率、再手术率及术后并发症(感染、脱位、骨折)均无显著差异。作者认为钛制锥形带槽非模块化柄可能提供更具成本效益的翻修选择。

要点

  • 非模块化柄成本显著低于模块化柄(模块化柄成本高120.8%,P<.001)。
  • 非模块化柄手术时间显著更长(193分钟 vs 163分钟,P=.029)。
  • 两组住院时间、再翻修率、再手术率及术后并发症均无显著差异。

核心结论

  • 非模块化组件在翻修全髋关节置换术中提供令人鼓舞的临床结果,且成本显著低于模块化组件。
  • 使用钛制锥形带槽非模块化组件可能较模块化组件为翻修全髋关节置换术提供更具成本效益的方法。

研究设计与样本

  • 回顾性识别2013年1月1日至2017年9月30日间所有使用模块化或非模块化股骨柄的翻修全髋关节置换术病例。
  • 共纳入146例翻修全髋关节置换术(103例模块化柄、43例非模块化柄),平均随访29个月(范围3-59个月)。
  • 收集人口学资料(年龄、性别、美国麻醉医师协会评分)、手术细节(手术时间、假体成本)及临床结局(住院时间、脱位、感染、骨折、再手术、再翻修)。
  • 统计分析采用卡方检验和Student t检验分别处理分类变量和连续变量。

主要发现

  • 非模块化柄成本显著低于模块化柄(模块化柄成本高120.8%,P<.001)。
  • 非模块化组件手术时间显著更长(193分钟 vs 163分钟,P=.029)。
  • 住院时间两组无显著差异(P=.323)。
  • 股骨假体再翻修率两组无显著差异(P=.389),再手术率两组无显著差异(P=.383)。
  • 术后并发症两组无显著差异(P=.241),包括感染(P=.095)、脱位(P=.778)和骨折(P=.959)。

临床怎么用

  • 作者认为,钛制锥形带槽非模块化组件可能较模块化组件为翻修全髋关节置换术提供更具成本效益的方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Nonmodular and modular femoral stems have been associated with complications after revision total hip arthroplasty (rTHA). As such, the ideal femoral component for rTHA remains undecided. This study aims to report outcomes of titanium, tapered-fluted, modular and nonmodular femoral components in rTHA. METHODS: From January 1, 2013 to September 30, 2017, all rTHAs using modular or nonmodular femoral stems were identified. Demographic data including age, gender, and American Society of Anesthesiologists scores were collected. Surgical details including operative time and implant cost were also collected. Clinical outcomes including length of stay, dislocation, infection, fracture, reoperation, and re-revision were collected. Statistical analysis was performed using chi-square test and Student's t-test for all categorical and continuous variables, respectively. RESULTS: One hundred forty-six rTHA cases (103 modular and 43 nonmodular) were identified with an average follow-up of 29 months (range 3-59 months). Nonmodular stems had a significantly lower cost when compared to modular implants (modular stems 120.8% higher cost; P < .001). The surgical time of nonmodular components was significantly greater (193 minutes vs 163 minutes; P = .029). There were no differences observed in any other surgical details or clinical outcomes assessed, including length of stay (P = .323), rate of re-revision of the femoral implant (P = .389), rate of re-operation (P = .383), and postop complications (P = .241), including infection (P = .095), dislocation (P = .778), and fracture (P = .959). CONCLUSIONS: Nonmodular components provide encouraging clinical results with significantly lower costs compared to modular implants in rTHA. The use of titanium, tapered-fluted, nonmodular components may offer a more cost-effective approach to rTHA compared to their modular counterparts.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Clair AJ, Cizmic Z, Vigdorchik JM, et al. Nonmodular Stems Are a Viable Alternative to Modular Stems in Revision Total Hip Arthroplasty. J Arthroplasty. 2019. PMID: 31010773. doi:10.1016/j.arth.2019.03.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。