关节置换术后髋关节囊的生物力学:假体类型、手术入路与手术修复的影响
研究在8对尸体髋关节上测量内旋和外旋时关节囊对活动度的限制,比较髋关节表面置换术(HRA)、双动全髋关节置换术(DM-THA)和常规全髋关节置换术(THA)以及后方与前方关节囊切开的影响。结果显示HRA提供接近原生髋的活动度,DM-THA部分恢复关节囊功能,常规THA则丧失关节囊对活动度的限制功能。
要点
- HRA术后内旋/外旋活动度较原生髋增加5°至17°(9%至33%),接近原生。
- DM-THA术后活动度增加9°至61°(18%至121%),关节囊功能部分恢复。
- 常规THA术后活动度增加52°至100°(94%至199%),关节囊限制功能丧失。
核心结论
- 原生股骨头尺寸的假体与关节囊修复可保留关节置换术后的关节囊功能。
- 前方入路与后方入路对关节囊韧带的术后生物力学功能影响不同。
研究设计与样本
- 研究采用8对尸体髋关节,保留髋关节囊并去除软组织。
- 在控制的内旋和外旋下测量关节囊对活动度的限制,比较HRA、DM-THA和常规THA术前术后,右髋行后方关节囊切开,左髋行前方关节囊切开。
主要发现
- HRA术后内旋/外旋活动度较原生髋增加5°至17°(9%至33%),接近原生。
- DM-THA术后活动度增加9°至61°(18%至121%),关节囊功能部分恢复。
- 常规THA术后活动度增加52°至100°(94%至199%),关节囊对活动度的限制功能丧失。
- 在低屈伸位置,后方关节囊切开比前方提供更正常的功能,可能因为后方修复时关节囊被缩短。
- 在深度屈曲位置,前方关节囊切开功能更好。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The hip's capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. MATERIALS AND METHODS: Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips). RESULTS: Hip resurfacing provided a near-native ROM with between 5° to 17° increase in IR/ER ROM compared with the native hip for the different positions tested, which was a 9% to 33% increase. DM-THA generated a 9° to 61° (18% to 121%) increase in ROM. Conventional THA generated a 52° to 100° (94% to 199%) increase in ROM. Thus, for conventional THA, the capsule function that exerts a limit on ROM is lost. It is restored to some extent by DM-THA, and almost fully restored by hip resurfacing. In positions of low flexion/extension, the posterior capsulotomy provided more normal function than the anterior, possibly because the capsule was shortened during posterior repair. However, in deep flexion positions, the anterior capsulotomy functioned better. CONCLUSION: Native head-size and capsular repair preserves capsular function after arthroplasty. The anterior and posterior approach differentially affect postoperative biomechanical function of the capsular ligaments. Cite this article: Bone Joint J 2019;101-B:426-434.
引用
- Logishetty K, van Arkel RJ, Ng KCG, et al. Hip capsule biomechanics after arthroplasty: the effect of implant, approach, and surgical repair. Bone Joint J. 2019. PMID: 30929480. doi:10.1302/0301-620X.101B4.BJJ-2018-1321.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。