生物复合材料缝合锚钉在肩袖修复术后两年仍可见

Biocomposite Suture Anchors Remain Visible Two Years After Rotator Cuff Repair.
PubMed 文献 · Clin Orthop Relat Res · 2019-01-01

本研究回顾性纳入25例(84枚锚钉)肩袖修复患者,采用聚L-乳酸与β-磷酸三钙复合缝合锚钉,术后2.3±0.3年评估锚钉吸收、骨床直径、肌腱完整性及临床评分。结果显示90%锚钉仍可见,再撕裂者骨隧道较未撕裂者窄,WORC与Oxford评分与隧道增宽、液体膜分级、生物降解分级及再撕裂无关联。

要点

  • 术后2.3±0.3年,76/84(90%)锚钉仍有不同程度降解但可见。
  • 骨隧道基底部轻微增宽(0.4±1.4 mm),中段和顶部因骨长入而变窄。
  • 再撕裂组骨隧道(3.6±1.8 mm)较无再撕裂组(4.4±1.6 mm)窄,差异未达统计学显著(p=0.050)。

核心结论

  • 作者认为,外科医生在日常实践中应考虑这些植入物的吸收过程可能比迄今假设的更慢,但短期未发现与严重植入物相关并发症的关联。
  • 作者建议未来研究应关注成骨材料对吸收、肌腱愈合和临床结局的长期影响,以及不同肩袖重建技术中的整合过程。

研究设计与样本

  • 回顾性研究,2012年8月至2014年1月纳入36例患者,排除4例,7例(19%)失访,最终纳入25例(84枚植入物)。
  • 纳入标准:可修复的全层冈上肌腱撕裂、采用双排缝合桥技术修复、仅使用聚L-乳酸(PLLA)和β-磷酸三钙(TCP)复合缝合锚钉、至少2年随访。
  • 通过MRI评估植入物吸收、植入物周围液体膜、骨床直径和肌腱完整性(Sugaya分类),并与临床评分(WORC和Oxford肩关节评分)进行关联分析。
  • 观察者内信度为0.981(p < 0.001),观察者间信度为0.895(p < 0.001)。

主要发现

  • 随访2.3±0.3年时,大多数锚钉(76/84 [90%])仍有不同程度降解但可见。
  • 骨隧道基底部轻微增宽(0.4±1.4 mm),中段(0.1±1.1 mm)和顶部(1.4±1.7 mm)因骨长入而变窄。
  • 再撕裂患者(Sugaya 4-5级)骨隧道(3.6±1.8 mm)较无再撕裂患者(Sugaya 1-3级;4.4±1.6 mm)窄,平均差异0.782(95%CI:0.009-1.6),p = 0.050。
  • WORC和Oxford评分与隧道增宽量、液体膜分级、生物降解分级或肌腱再撕裂无关联。

关键数值与推荐

  • 植入物吸收和植入物周围液体膜采用四级量表系统评估。
  • 肌腱完整性根据Sugaya分类评估。
  • 骨隧道直径在每个锚钉纵向中心轴的三个不同点测量。

临床怎么用

  • 作者认为,外科医生在日常实践中应考虑这些植入物的吸收过程可能比迄今假设的更慢。
  • 短期未发现与严重植入物相关并发症的关联。

局限性

  • 本研究为回顾性研究。
  • 7例(19%)患者失访。
  • 作者建议未来研究应关注成骨材料对吸收、肌腱愈合和临床结局的长期影响,以及不同肩袖重建技术中的整合过程。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Biocomposite suture anchors containing osteoconductive materials have gained popularity in rotator cuff repairs. However, little is known about the influence of the addition of osteoconductive materials on implant resorption, bone reaction, tendon healing, and clinical outcomes scores. QUESTIONS/PURPOSES: (1) What percentage of suture anchors were not completely resorbed 2 years after implantation? (2) What are the diameters of the bone bed in relation to the implant? (3) Is tendon integrity correlated with bone tunnel diameter? (4) Is there an association between tunnel widening, periimplant fluid film grade, biodegradation grade, and retear with clinical outcomes scores, such as the Western Ontario Rotator Cuff Index (WORC) and the Oxford Shoulder Score (OSS)? METHODS: Thirty-six patients were enrolled from August 2012 to January 2014. The following inclusion criteria were applied: (1) reparable full-thickness supraspinatus tendon tears, (2) double-row suture bridge techniques applied for supraspinatus repair, (3) use of biocomposites suture anchor implants composed of poly L-lactic acid (PLLA) and β-tricalcium phosphate (TCP) exclusively, and (4) a minimum of 2 years followup. Four patients met the exclusion criteria, and seven of 36 patients (19%) were lost to followup. Thereby, 25 patients (84 implants) were included in this retrospective study. To answer the study's questions, the following methods were applied: (1) The resorption of the implants and periimplant fluid film were assessed on MRI using a four-stage scale system, (2) bone bed diameter was measured on MRI at three different points on the longitudinal central axis of each anchor, (3) tendon integrity was evaluated on MRI according to the Sugaya classification and correlated to bone tunnel diameter, and (4) assessed tunnel diameters, periimplant fluid film grade, biodegradation grade, and tendon condition were related to clinical outcomes scores at the time of followup (2.3 ± 0.3 years). The intraobserver reliability was 0.981 (p < 0.001) and interobserver reliability was 0.895 (p < 0.001). RESULTS: At 2.3 ± 0.3 years, most analyzed suture anchors (76 of 84 [90%]) were, with varying degrees of degradation, still visible. Bone tunnels showed minor widening (0.4 ± 1.4 mm) at the base, but osseous ingrowth was detected as narrowing at the middle (0.1 ± 1.1 mm) and at the apex (1.4 ± 1.7 mm) of the implants. Patients with retears (Sugaya Grades 4-5) had narrower tunnels (3.6 ± 1.8 mm) than patients without retears (Sugaya Grades 1-3; 4.4 ± 1.6 mm; mean difference, 0.782 [95% confidence interval {CI}: 0.009-1.6]; p = 0.050). WORC and Oxford scores were not associated with the tunnel widening amount, fluid film grade, biodegradation grade, or tendon retear. CONCLUSIONS: In light of the results of the present study, surgeons should consider in their daily practice that the resorption process of these implants may be slower than assumed so far, but no association with severe implant-related complications has been found in the short term. Future studies should focus on the evaluation of the effects of osteoconductive materials on resorption, tendon healing, and clinical outcomes in the long term and on the integration process in different rotator cuff reconstruction techniques. LEVEL OF EVIDENCE: Level IV, therapeutic study.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Sgroi M, Friesz T, Schocke M, et al. Biocomposite Suture Anchors Remain Visible Two Years After Rotator Cuff Repair. Clin Orthop Relat Res. 2019. PMID: 30908350. doi:10.1097/CORR.0000000000000665

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。