文献速递关节外科

高髋中心降低动态髋关节活动度并增加髋关节负荷:单侧发育性髋关节发育不良全髋关节置换患者的步态分析研究

High Hip Center Reduces the Dynamic Hip Range of Motion and Increases the Hip Load: A Gait Analysis Study in Hip Arthroplasty Patients With Unilateral Developmental Dysplasia.
PubMed 文献 · J Arthroplasty · 2019-02-18

纳入40例因单侧Crowe III-IV型发育性髋关节发育不良继发髋关节骨关节炎行全髋关节置换并完成5年随访的患者,比较解剖髋中心重建(20例)与高髋中心重建(20例)的步态特征。高髋中心组术侧髋关节伸展角度显著低于解剖组,纵向髋关节力显著高于解剖组。作者认为高髋中心技术增加髋关节负荷并限制动态活动度,可能降低假体生存率并增加跌倒风险。

要点

  • 高髋中心组术侧髋关节伸展角度显著低于解剖髋中心组(P = .04)。
  • 高髋中心组纵向髋关节力显著高于解剖髋中心组(P = .04)。
  • 作者认为高髋中心技术增加髋关节负荷并限制动态活动度,可能降低假体生存率并增加跌倒风险。

核心结论

  • 高髋中心技术增加髋关节负荷并降低动态活动度,可能降低假体生存率并增加跌倒风险。
  • 作者认为单侧全髋关节置换的发育性髋关节发育不良患者应尽可能解剖重建髋中心。

研究设计与样本

  • 共纳入40例因单侧Crowe III-IV型发育性髋关节发育不良继发髋关节骨关节炎行全髋关节置换并完成5年随访的患者。
  • 第1组20例接受解剖髋中心重建,第2组20例接受高髋中心重建,进行步态分析并比较步态特征。

主要发现

  • 两组的平均时间空间参数相似。
  • 术侧髋关节伸展角度第2组为-9.11 ± 8.92,显著低于第1组的-1.87 ± 11.51(P = .04)。
  • 平均纵向髋关节力第2组为8.92 N/kg ± 0.54,显著高于第1组的8.16 N/kg ± 0.66(P = .04)。
  • 高髋中心技术显示增加髋关节负荷并限制动态活动度。

临床怎么用

  • 作者认为单侧全髋关节置换的发育性髋关节发育不良患者应尽可能解剖重建髋中心。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Long-term favorable clinical outcomes of anatomical or high hip center techniques in total hip arthroplasty (THA) are reported in patients with developmental dysplasia of the hip (DDH). However, there is little information about the effect of the hip center location on gait characteristics. The purpose of this study was to compare these surgical techniques with gait analysis, analyze the effect of the hip rotation center location on gait parameters, and discuss the possible problems that may arise. METHODS: A total of 40 patients who underwent THA due to unilateral coxarthrosis secondary to Crowe type III-IV DDH and completed 5 years of follow-up were included in the study. Group 1 included 20 patients who underwent anatomical hip center reconstruction, while group 2 included 20 patients who underwent high hip center reconstruction. Gait analysis was performed, and the groups were compared according to the gait characteristics. RESULTS: The mean temporospatial values were similar between the groups. The extension of the operated side was significantly lower in group 2 (-9.11 ± 8.92) than in group 1 (-1.87 ± 11.51) (P = .04). The mean longitudinal hip joint force was found to be significantly higher in group 2 (8.92 N/kg ± 0.54) than in group 1 (8.16 N/kg ± 0.66) (P = .04). The high hip center technique has been shown to increase the load on the hip and restrict the dynamic range of motion. CONCLUSION: The high hip center technique can decrease the survival of the implant and increase the fall risk as it increases the load on the hip and reduces the dynamic range of motion. The hip center should be reconstructed anatomically when possible in DDH patients who undergo unilateral THA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Karaismailoglu B, Erdogan F, Kaynak G, et al. High Hip Center Reduces the Dynamic Hip Range of Motion and Increases the Hip Load: A Gait Analysis Study in Hip Arthroplasty Patients With Unilateral Developmental Dysplasia. J Arthroplasty. 2019. PMID: 30857951. doi:10.1016/j.arth.2019.02.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。