固定承重平台翻修全膝关节置换术矫正轴向假体旋转不良可改善活动度与患者报告结局评分
回顾性分析42例因轴向假体旋转不良行无菌性翻修的全膝关节置换术,翻修后膝关节协会评分从52±22改善至84±25(P<.001),屈曲度从105±21°增加至115±13°(P=.001)。在僵硬背景下翻修可显著改善评分与活动度,在不稳定背景下翻修可显著改善评分但不影响活动度。单组件或双组件翻修及是否使用更高限制性假体之间,术后评分与屈曲度无统计学显著差异。
要点
- 因轴向旋转不良行翻修全膝关节置换术可改善膝关节协会评分与活动度。
- 不稳定背景下翻修可显著改善评分,但活动度无显著改善。
- 僵硬背景下翻修可显著改善评分与活动度。
核心结论
- 因轴向对线不良行翻修全膝关节置换术可改善临床结局评分与功能性活动度。
研究设计与样本
- 回顾性分析了42例因轴向假体旋转不良行无菌性翻修的全膝关节置换术。
主要发现
- 孤立性轴向旋转不良翻修后膝关节协会评分从52±22改善至84±25(P<.001)。
- 孤立性轴向旋转不良翻修后屈曲度从105±21°增加至115±13°(P=.001)。
- 不稳定背景下翻修可显著改善膝关节协会评分(P<.001),但不影响活动度(P=.172)。
- 僵硬背景下翻修可显著改善膝关节协会评分(P<.001)与活动度(P=.002)。
- 孤立性轴向旋转不良翻修中,单组件与双组件翻修的术后膝关节协会评分(P=.889)与最终屈曲度(P=.629)无统计学显著差异;是否使用更高限制性假体的术后膝关节协会评分(P=.956)与最终屈曲度(P=.541)也无统计学显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Suboptimal implant rotation has consequences with respect to knee kinematics and clinical outcomes. We evaluated the functional outcomes of revision total knee arthroplasty (TKA) for poor axial implant rotation. METHODS: We retrospectively reviewed 42 TKAs undergoing aseptic revision for poor axial implant rotation. We assessed improvements in Knee Society Score (KSS) and final range of motion (ROM). Subgroup analyses were performed for preoperative instability and stiffness, as well as the number of components revised and level of implant constraint used. RESULTS: Revision for poor axial rotation in isolation improved KSS from 52 ± 22 to 84 ± 25 (P < .001), and flexion increased from 105 ± 21° to 115 ± 13° (P = .001). Revision in the setting of instability significantly improved the KSS (P < .001) but did not affect ROM (P = .172). Revision in the setting of stiffness significantly improved both KSS (P < .001) and ROM (P = .002). There was no statistically significant difference between the postoperative KSS (P = .889) and final knee flexion (P = .629) with single- or both-component revision TKA for isolated poor axial rotation or between the postoperative KSS (P = .956) and final knee flexion (P = .541) with or without the use of higher constraint during revision TKA for isolated poor axial rotation. CONCLUSION: Revision TKA for poor axial alignment improves clinical outcomes scores and functional ROM.
引用
- Amanatullah DF, Lichstein PM, Lundergan WG, et al. Improved Range of Motion and Patient-Reported Outcome Scores With Fixed-Bearing Revision Total Knee Arthroplasty for Suboptimal Axial Implant Rotation. J Arthroplasty. 2019. PMID: 30853158. doi:10.1016/j.arth.2019.02.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。