文献速递关节外科

多孔钽金属杯与增强块重建髋臼骨缺损在翻修全髋关节置换术中十年随访

Reconstruction of acetabular defects with porous tantalum shells and augments in revision total hip arthroplasty at ten-year follow-up.
PubMed 文献 · Bone Joint J · 2019-01-01

该研究评估了2006至2010年间60例患者(62髋)使用小梁金属杯联合增强块进行髋臼翻修的中远期效果,51例患者(53髋)获得至少七年完整随访。平均十年假体生存率为92.5%,Harris髋关节评分从术前55分显著改善至末次随访81分,作者认为该技术长期结果优异。

要点

  • 平均十年髋臼假体生存率为92.5%
  • 3髋(5.6%)因无菌性松动需再翻修,1髋(1.9%)因感染需翻修
  • Harris髋关节评分从术前55分改善至末次随访81分(p < 0.001)

核心结论

  • 使用小梁金属杯与增强块重建髋臼骨缺损的长期结果优异。
  • 作者认为每位患者均应进行杯的辅助螺钉固定。
  • 作者建议对于骨盆不连续应考虑替代技术。

研究设计与样本

  • 2006至2010年间,60例患者(62髋)因髋臼骨缺损接受小梁金属杯联合增强块的髋臼翻修术。
  • 51例患者(53髋)获得至少七年完整随访并被纳入研究,其中男性15例(29.4%),女性36例(70.6%)。
  • 翻修时平均年龄64.6岁(范围28至85岁)。
  • 骨缺损分型:Paprosky IIA型3例(5.2%),IIB型13例(24.5%),IIC型6例(11.3%),IIIA型22例(41.5%),IIIB型9例(17%)。
  • 5例患者(9.4%)合并骨盆不连续。

主要发现

  • 术后平均十年髋臼假体总体生存率为92.5%。
  • 3髋(5.6%)因无菌性松动需再翻修,其中2髋因杯螺钉固定不足导致失败,1髋因骨盆不连续导致失败。
  • 1髋(1.9%)因感染需翻修。
  • Harris髋关节评分从术前平均55分(范围35至68)显著改善至末次随访平均81分(范围68至99)(p < 0.001)。

关键数值与推荐

  • 术后平均十年髋臼假体总体生存率为92.5%。
  • Harris髋关节评分从术前55分改善至末次随访81分(p < 0.001)。

临床怎么用

  • 作者认为每位患者均应进行小梁金属杯的辅助螺钉固定。
  • 作者建议对于骨盆不连续应考虑替代技术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The use of trabecular metal (TM) shells supported by augments has provided good mid-term results after revision total hip arthroplasty (THA) in patients with a bony defect of the acetabulum. The aim of this study was to assess the long-term implant survivorship and radiological and clinical outcomes after acetabular revision using this technique. PATIENTS AND METHODS: Between 2006 and 2010, 60 patients (62 hips) underwent acetabular revision using a combination of a TM shell and augment. A total of 51 patients (53 hips) had complete follow-up at a minimum of seven years and were included in the study. Of these patients, 15 were men (29.4%) and 36 were women (70.6%). Their mean age at the time of revision THA was 64.6 years (28 to 85). Three patients (5.2%) had a Paprosky IIA defect, 13 (24.5%) had a type IIB defect, six (11.3%) had a type IIC defect, 22 (41.5%) had a type IIIA defect, and nine (17%) had a type IIIB defect. Five patients (9.4%) also had pelvic discontinuity. RESULTS: The overall survival of the acetabular component at a mean of ten years postoperatively was 92.5%. Three hips (5.6%) required further revision due to aseptic loosening, and one (1.9%) required revision for infection. Three hips with aseptic loosening failed, due to insufficient screw fixation of the shell in two and pelvic discontinuity in one. The mean Harris Hip Score improved significantly from 55 (35 to 68) preoperatively to 81 points (68 to 99) at the latest follow-up (p < 0.001). CONCLUSION: The reconstruction of acetabular defects with TM shells and augments showed excellent long-term results. Supplementary screw fixation of the shell should be performed in every patient. Alternative techniques should be considered to address pelvic disconinuity. Cite this article: Bone Joint J 2019;101-B:311-316.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Löchel J, Janz V, Hipfl C, et al. Reconstruction of acetabular defects with porous tantalum shells and augments in revision total hip arthroplasty at ten-year follow-up. Bone Joint J. 2019. PMID: 30813786. doi:10.1302/0301-620X.101B3.BJJ-2018-0959.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。