文献速递关节外科

全膝关节手术平衡中韧带力与接触力的关系

Relationship Between Ligament Forces and Contact Forces in Balancing at Total Knee Surgery.
PubMed 文献 · J Arthroplasty · 2019-02-18

本研究构建模拟人工膝关节及侧副韧带的测试装置,在屈膝过程中测量不同股骨假体位置下的韧带力与胫骨内外侧接触力,并用回归分析研究其相关性。结果显示内外侧韧带力之和与接触力之和呈线性相关(相关系数0.98),内侧和外侧单独相关性分别为0.85和0.88,超过80%的点在±25%偏差范围内。作者认为在手术通常达到的平衡精度内,侧副韧带力与髁接触力线性相关,不同平衡参数可互换使用。

要点

  • 内外侧韧带力之和与接触力之和呈线性相关,相关系数0.98。
  • 内侧和外侧单独相关性分别为0.85和0.88,超过80%的点在±25%偏差内。
  • 作者认为在手术通常平衡精度内,侧副韧带力与髁接触力线性相关,不同平衡参数可互换使用。

核心结论

  • 在手术通常达到的平衡精度内,侧副韧带力与髁接触力线性相关,不同平衡参数可互换使用。

研究设计与样本

  • 构建模拟人工膝关节及侧副韧带的测试装置,在屈膝过程中测量不同股骨假体位置下的韧带力与胫骨内外侧接触力,并用回归分析研究相关性。

主要发现

  • 内外侧韧带力之和与接触力之和呈线性相关,相关系数0.98。
  • 内侧和外侧单独相关性分别为0.85和0.88,超过80%的点在±25%偏差范围内。
  • 与线性相关的偏差与不同屈膝角度下内外侧股骨-胫骨接触点位置的差异有关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Spacer blocks, tensors, or instrumented tibial trials are current methods of balancing the knee during surgery but there are no current techniques for measuring ligament forces. Our goal was to study the relationship between the collateral ligament forces and the condylar contact forces to determine whether there was equivalence. METHODS: A test rig was constructed modeling an artificial knee joint with collateral ligaments. The ligament forces as well as the lateral and medial tibial contact forces were measured during flexion for different positions of the femoral component on the femur, producing a set of forces for the simulated conditions. A regression analysis was used to study the correlation between the ligament and contact forces. RESULTS: The combined medial and lateral ligament and contact forces showed a linear relation with a correlation coefficient of 0.98. For the medial and lateral sides separately, the correlations were 0.85 and 0.88, respectively, with more than 80% of points within a ±25% deviation from the linear relations. This deviation from the linear correlation is linked to differences in medial-lateral femoral-tibial contact point locations at different flexion angles. CONCLUSION: Within balancing accuracies generally achieved at surgery, the collateral ligament forces were linearly correlated to the condylar contact forces. These forces can also be equally correlated to the distraction forces as well as the moments at which condylar liftoff would occur from varus-valgus moments. This indicated a unification of the different balancing parameters, and hence such quantitative methods can be used interchangeably.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Sanz-Pena I, Zapata GE, Verstraete MA, et al. Relationship Between Ligament Forces and Contact Forces in Balancing at Total Knee Surgery. J Arthroplasty. 2019. PMID: 30890388. doi:10.1016/j.arth.2019.02.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。