膝关节置换假体旋转不良在短期至中期不影响功能或生活质量

Knee Arthroplasty Component Malrotation Does Not Affect Function or Quality of Life in the Short to Medium Term.
PubMed 文献 · J Arthroplasty · 2019-03-01

回顾性分析前瞻性收集的初次全膝关节置换数据,评估股骨、胫骨及组合假体旋转对功能(膝关节协会评分)、疼痛与生活质量(SF-12)及假体失败的影响。随访5年未发现旋转与功能或生活质量存在临床相关关联,但组合假体旋转不良者总体疼痛评分改善程度低于无旋转不良者。

要点

  • 随访5年,假体旋转不良与功能或生活质量无临床相关关联。
  • 组合假体旋转不良者总体疼痛评分改善程度低于无旋转不良者。
  • 中期假体旋转不良可能导致疼痛改善程度较术前下降。

核心结论

  • 中期假体旋转不良可能导致疼痛改善程度较术前下降,但不显著影响功能或生活质量。

研究设计与样本

  • 回顾性研究,采用前瞻性收集的数据,评估初次全膝关节置换中股骨、胫骨及组合假体旋转的影响。
  • 主要结局为膝关节协会评分评估的功能、SF-12评估的疼痛与生活质量,次要结局为假体失败。

主要发现

  • 随访5年未发现功能或生活质量与假体旋转之间存在临床相关关联。
  • 组合假体旋转不良(股骨旋转加胫骨旋转导致整体假体内旋)者总体疼痛评分改善程度低于无旋转不良者。

关键数值与推荐

  • 旋转不良定义:股骨假体内旋偏离中立位或外旋大于5°,胫骨假体内旋大于6°,或两组件组合内旋偏离中立位。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Component rotation in total knee arthroplasty is thought to affect patella tracking, flexion gap, and balancing and hence is hypothesized to affect function, pain, and longevity. Few studies have directly correlated post-operative component rotation to function and quality of life in the short to medium term post-operatively, with findings in the current literature conflicting. METHODS: A retrospective study of prospectively collected data was used to determine the effect of femoral, tibial, and combined component rotation in primary total knee arthroplasty with primary outcomes being function as measured by the Knee Society Score, pain and quality of life as measured by the Short-Form 12 score, and secondary outcome being prosthesis failure. Malrotation was defined using the current literature as being internally rotated from neutral, or externally rotated greater than 5° for the femoral component, internally rotated greater than 6° for the tibial component, or internally rotated from neutral for the 2 components combined. RESULTS: No clinically relevant correlation between function or quality of life and component rotation could be found at 5 years. However, it was noted that those patients with combined component malrotation (femoral rotation added to tibial rotation resulting in overall component internal rotation) improved less in overall pain scores than those that were not malrotated. CONCLUSION: In the mid-term, component malrotation may result in a decreased level of improvement from pain compared to pre-operative results. However, component malrotation does not make a significant difference to function or quality of life. LEVEL OF EVIDENCE: Level III: Therapeutic Study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Babazadeh S, Dowsey MM, Vasimalla MG, et al. Knee Arthroplasty Component Malrotation Does Not Affect Function or Quality of Life in the Short to Medium Term. J Arthroplasty. 2019. PMID: 30905638. doi:10.1016/j.arth.2019.02.056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。