非骨水泥带凹槽长柄半髋关节置换术治疗髋半髋关节置换术后Vancouver B2和B3型假体周围骨折
回顾性病例对照研究比较46例翻修为半髋关节置换(HA组)与31例翻修为全髋关节置换(THA组)治疗髋半髋关节置换术后Vancouver B2和B3型假体周围骨折。THA组输血需求和住院时间显著更高;两组末次随访Merle d'Aubigné评分(P=0.121)和Katz评分(P=0.214)相似,但两组术后髋关节功能均较术前显著下降(P=0.001)。作者认为长柄非骨水泥双极半髋翻修联合钢丝环扎和松质骨异体植骨是有效选择。
要点
- THA组输血需求和住院时间显著高于HA组。
- 末次随访两组Merle d'Aubigné评分(P=0.121)和Katz评分(P=0.214)无显著差异。
- HA组除1例外骨折均愈合,HA组无脱位而THA组有3例脱位。
核心结论
- 采用长柄非骨水泥双极半髋翻修联合钢丝环扎和松质骨异体植骨治疗髋半髋关节置换术后Vancouver B2和B3型假体周围骨折,在骨折愈合和假体稳定性方面是有效选择,并发症率低。
- 但两组均观察到显著的功能损害。
研究设计与样本
- 回顾性病例对照研究,比较46例翻修为半髋关节置换(HA组)和31例翻修为全髋关节置换(THA组)的患者。
- 功能结局采用Merle d'Aubigné评分和基于日常生活活动能力的Katz量表评估。
- 合并症采用Charlson指数评估,认知功能采用简易智力测试评分评估,并进行了影像学评估。
主要发现
- HA组平均术后随访3.3年(范围2-4年),THA组平均3.9年(范围2-5年)。
- THA组输血需求和住院时间显著高于HA组。
- 术后两组平均髋关节功能均显著下降(P=0.001),但末次随访平均Merle评分(P=0.121)和Katz评分(P=0.214)相似。
- 两组在疼痛或丧失生活独立性方面无显著差异。
- HA组除1例外所有骨折均愈合;HA组无脱位,THA组有3例脱位。
关键数值与推荐
- HA组末次随访平均Merle评分与THA组比较P=0.121,无显著差异。
- HA组末次随访平均Katz评分与THA组比较P=0.214,无显著差异。
- 两组术后平均髋关节功能较术前显著下降,P=0.001。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The purpose of this study was to assess the effectiveness of a cementless, modular, fluted, long-stem hemiarthroplasty for the treatment of Vancouver type B2 and B3 periprosthetic femoral fracture around hip hemiarthroplasty. METHODS: This was a retrospective case-control study comparing 46 patients revised to hemiarthroplasty (HA group) and 31 revised to total hip arthroplasty (THA group). Functional outcome was evaluated by the Merle d'Aubigné score, and the Katz scale based on activities of daily living. Comorbidity was assessed by the Charlson index, and cognitive function by a mini-mental test score. Radiological evaluation was also performed. RESULTS: Mean postoperative follow-up was 3.3 (range, 2-4) years in the HA group and 3.9 (range, 2-5) in the THA group. The need for transfusion and hospital stay were significantly higher in the THA group. Postoperatively, both groups had a significant decrease in mean hip function (P = .001) although the mean Merle (P = .121) and Katz (P = .214) scores were similar at final follow-up. Likewise, there were no significant differences between groups in pain or loss of life independence. All fractures were united but one in the HA group. There were no dislocations in the HA group, and 3 in the THA group. CONCLUSION: The management of Vancouver B2 and B3 periprosthetic femoral fracture around hemiarthroplasties with a long-stem revision cementless bipolar hemiarthroplasty, supplemented with wire cerclages and cancellous allograft, was an effective option in terms of fracture healing and stability of the implant with a low rate of complications. Nevertheless, a significant functional impairment was also observed in either group.
引用
- Lizaur-Utrilla A, Gonzalez-Parreño S, Miralles-Muñoz FA, et al. Cementless, Fluted, Long-Stem Hemiarthroplasty for Vancouver B2 and B3 Periprosthetic Fractures Around Hip Hemiarthroplasty. J Arthroplasty. 2019. PMID: 30879875. doi:10.1016/j.arth.2019.02.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。