文献速递关节外科

计算机辅助运动学全膝关节置换术中的内外侧间隙松弛差异

Medial and lateral gap laxity differential in computer-assisted kinematic total knee arthroplasty.
PubMed 文献 · Bone Joint J · 2019-01-01

本研究随访192例由单一术者完成的计算机辅助运动学全膝关节置换术,平均随访3.5年(2至5年),评估术中间隙松弛度、假体位置及术后站立位三足X线片关节角,并结合患者报告结局分析。结果显示,术后下肢力线不影响结局,站立位髋-膝-踝角是关节线汇聚角的唯一正向预测因素(p<0.001),外侧屈曲间隙松弛度增加始终与更好结局相关,且与髋-膝-踝角、关节线汇聚角及外侧伸直间隙松弛度不相关,仅11%病例形成矩形屈曲间隙,约三分之一病例需 minor release。

要点

  • 站立位髋-膝-踝角是运动学全膝关节置换术后关节线汇聚角的唯一正向预测因素(p<0.001)
  • 外侧屈曲间隙松弛度增加与更好结局相关,且与伸直间隙平衡无关
  • 仅11%病例形成矩形屈曲间隙,约三分之一病例需 minor release

核心结论

  • 站立位髋-膝-踝角是运动学全膝关节置换术中关节线汇聚角的主要决定因素。
  • 外侧屈曲间隙松弛度始终与更好结局相关,且不影响伸直间隙平衡。
  • 部分病例仍需 minor release,尤其是术前畸形较大的肢体。

研究设计与样本

  • 由单一术者完成的192例计算机辅助运动学全膝关节置换术,平均随访3.5年(2至5年)。
  • 患者中男性116例(60%)、女性76例(40%),平均年龄65岁(48至88岁)。
  • 结局指标包括术中间隙松弛度测量、假体位置、术后三足站立位X线片关节角及患者报告结局(EQ-5D VAS、KOOS、KOOS JR、OKS)。

主要发现

  • 术后下肢力线不影响结局。
  • 站立位髋-膝-踝角是关节线汇聚角的唯一正向预测因素(p<0.001)。
  • 外侧屈曲间隙松弛度增加始终与更好结局相关。
  • 外侧屈曲间隙松弛度与髋-膝-踝角、关节线汇聚角及外侧伸直间隙松弛度均不相关。
  • 约三分之一病例需要 minor release。

关键数值与推荐

  • 仅11%的病例形成矩形屈曲间隙。
  • 外侧屈曲间隙松弛度增加与更好结局相关。
  • 约三分之一病例需 minor release。
  • 站立位髋-膝-踝角是关节线汇聚角的唯一正向预测因素(p<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases? PATIENTS AND METHODS: A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS). RESULTS: Postoperative limb alignment did not affect outcomes. The standing hip-knee-ankle (HKA) angle was the sole positive predictor of the joint line convergence angle (JLCA) (p < 0.001). Increasing lateral flexion gap laxity was consistently associated with better outcomes. Lateral flexion gap laxity did not correlate with HKA angle, the JLCA, or lateral extension gap laxity. Minor releases were required in one third of cases. CONCLUSION: The standing HKA angle is the primary determinant of the JLCA in KTKA. A rectangular flexion gap is produced in only 11% of cases. Lateral flexion gap laxity is consistently associated with better outcomes and does not affect balance in extension. Minor releases are sometimes required as well, particularly in limbs with larger preoperative deformities. Cite this article: Bone Joint J 2019;101-B:331-339.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. McEwen P, Balendra G, Doma K, et al. Medial and lateral gap laxity differential in computer-assisted kinematic total knee arthroplasty. Bone Joint J. 2019. PMID: 30813796. doi:10.1302/0301-620X.101B3.BJJ-2018-0544.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。