全髋关节置换术基于手术入路的机械并发症:一项大型单机构队列研究
该回顾性单机构队列研究纳入2010至2016年连续16,186例全髋关节置换术,比较直接前入路(DA,n=5465)、直接外侧入路(DL,n=8561)和后外侧入路伴软组织修复(PL,n=2160)术后2年内机械并发症风险。调整后DL、DA、PL的2年不稳定风险分别为0.17%、0.74%、1.74%;DA的股骨失败(骨折或松动)调整发生率1.20%高于DL的0.58%和PL的0.47%。作者结论认为DL入路总体机械并发症风险最低。
要点
- 调整后2年不稳定风险DL为0.17%、DA为0.74%、PL为1.74%。
- DA的股骨失败调整发生率为1.20%,高于DL的0.58%和PL的0.47%。
- 即使伴软组织修复,PL入路的不稳定发生率仍较高。
核心结论
- 即使伴软组织修复,PL入路的不稳定发生率仍较高。
- DA在降低脱位的同时,股骨失败风险较高也须考虑。
- DL入路似乎赋予最低的总体机械并发症风险。
研究设计与样本
- 回顾性研究纳入2010至2016年连续16,186例全髋关节置换术。
- 排除翻修或转换全髋关节置换术、因髋部骨折、假体召回或术者学习期内的病例。
- 按入路分为直接前入路(DA,n=5465)、直接外侧入路(DL,n=8561)和后外侧入路伴软组织修复(PL,n=2160)。
- 主要分析为事件时间Cox回归,校正患者和术者特征。
主要发现
- 与DL相比,DA和PL的机械并发症风险均更高。
- 调整后2年内不稳定风险DL为0.17%、DA为0.74%、PL为1.74%。
- 假体周围骨折和松动的风险在PL与DL相似,但DA风险增加。
- 股骨失败(包括骨折或松动)在DA更常见,调整发生率DA为1.20% vs DL为0.58%、PL为0.47%。
关键数值与推荐
- 调整后2年不稳定风险:DL 0.17%、DA 0.74%、PL 1.74%。
- 股骨失败调整发生率:DA 1.20% vs DL 0.58%和PL 0.47%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The influence of surgical approach on risk of early postoperative mechanical complications after total hip arthroplasty (THA) continues to be a focus of debate. We performed the first single-institution study on risk of early operative and nonoperative mechanical complications after THA based on approach, with the hypothesis that there would be no clinically significant difference with modern surgical methods. METHODS: A retrospective study was conducted on 16,186 consecutive THA performed from 2010 to 2016. Revision or conversion THA and cases performed for hip fracture, with recalled prostheses, or during a surgeon's learning period were excluded. THAs were performed using direct anterior (DA; n = 5465), direct lateral (DL; n = 8561), or posterolateral approach with soft tissue repair (PL; n = 2160). All mechanical complications within the first 2 years were identified. The primary analysis was a time to event Cox regression, accounting for both patient and surgeon characteristics. RESULTS: Compared with the DL approach, risk of mechanical complications was higher for both DA and PL. Adjusted risk of instability within 2 years was 0.17%, 0.74%, and 1.74% for DL, DA, and PL, respectively. While occurring at similar rates with the PL and DL approaches, the risk of periprosthetic fracture and loosening increased with DA. Consequently, femoral failure, including fracture or loosening, occurred more frequently for DA, with an adjusted incidence of 1.20% vs 0.58% and 0.47%, with DL and PL. CONCLUSION: Even with soft tissue repair, instability continues to occur with increased frequency with the PL approach. While reducing dislocation, a higher risk of femoral failure with DA must also be considered. Nevertheless, the DL approach appears to confer the lowest overall risk of mechanical complications.
引用
- Fleischman AN, Tarabichi M, Magner Z, et al. Mechanical Complications Following Total Hip Arthroplasty Based on Surgical Approach: A Large, Single-Institution Cohort Study. J Arthroplasty. 2019. PMID: 30910246. doi:10.1016/j.arth.2019.02.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。