旋转铰链型翻修全膝关节置换术治疗严重关节纤维化
本研究将34例因关节纤维化接受旋转铰链型翻修全膝关节置换术的患者与68例未使用旋转铰链型假体的翻修患者进行匹配比较,平均随访6年。旋转铰链组活动弧度平均增加20°(74°至94°),非旋转铰链组增加12°(87°至99°)(P=0.048);旋转铰链组10年无任何翻修生存率为54%,非旋转铰链组为90%(P=0.03)。作者结论认为旋转铰链型翻修可改善活动弧度并减少手法松解次数,但再翻修风险更高。
要点
- 旋转铰链组活动弧度平均增加20°(74°至94°),非旋转铰链组增加12°(87°至99°)(P=0.048)。
- 旋转铰链组10年无任何翻修生存率54%,非旋转铰链组90%(P=0.03)。
- 旋转铰链组40%的翻修与衬垫和轴套更换相关。
核心结论
- 在本系列中,因关节纤维化接受旋转铰链型翻修全膝关节置换术的患者活动弧度改善20°,手法松解次数减少一半,但旋转铰链组再翻修风险更高。
研究设计与样本
- 将34例因关节纤维化接受旋转铰链型翻修全膝关节置换术的患者与68例未使用旋转铰链型假体的翻修患者进行匹配比较,平均年龄63岁,62%为女性,平均体重指数31 kg/m2,平均随访6年(范围2至15年)。
主要发现
- 旋转铰链组活动弧度平均增加20°(74°至94°),非旋转铰链组增加12°(87°至99°)(P=0.048)。
- 旋转铰链组行2次手法松解,非旋转铰链组行9次(P=0.2)。
- 两组膝关节学会评分均显著增加(分别为P=0.01和P<0.001)。
- 10年无因无菌性松动翻修生存率旋转铰链组为83%,非旋转铰链组为96%(P=0.44)。
- 10年无任何翻修生存率旋转铰链组为54%,非旋转铰链组为90%(P=0.03);旋转铰链组40%的翻修与衬垫和轴套更换相关。
局限性
- 证据等级为III级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Revision total knee arthroplasty (TKA) for arthrofibrosis is fraught with challenges. Because rotating-hinge (RH) prostheses do not rely on ligaments for stability, a more aggressive soft-tissue release is possible. The goal of this study was to report arc of motion, Knee Society scores, and implant survivorship in patients with arthrofibrosis revised with an RH. METHODS: Thirty-four patients revised with an RH for arthrofibrosis were matched to 68 patients revised without an RH. The mean age was 63 years, 62% were female, mean body mass index was 31 kg/m2, and mean follow-up was 6 years (range, 2-15 years). RESULTS: The mean arc of motion increased 20° (74°-94°) in the RH group versus 12° (87°-99°) in the non-RH group (P = .048). Two manipulations under anesthesia were performed in the RH group compared to 9 in the non-RH group (P = .2). Knee Society scores increased significantly in both groups (P = .01 and P < .001, respectively). Survivorship free of revision for aseptic loosening at 10 years was 83% in the RH group versus 96% in the non-RH group (P = .44). Survivorship free of any revision at 10 years was 54% in the RH group and 90% in the non-RH group (P = .03). Forty percent of the revisions in the RH group were related to insert and bushing exchanges. CONCLUSION: In this series, patients with arthrofibrosis revised to an RH TKA had a 20° improvement in arc of motion and manipulations under anesthesia were half as common. However, there was a higher risk of re-revision in the RH group. LEVEL OF EVIDENCE: III.
引用
- Bingham JS, Bukowski BR, Wyles CC, et al. Rotating-Hinge Revision Total Knee Arthroplasty for Treatment of Severe Arthrofibrosis. J Arthroplasty. 2019. PMID: 30819621. doi:10.1016/j.arth.2019.01.072
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。