全膝关节置换术中股骨切迹是否影响假体周围骨折:一项前瞻性研究
该单中心前瞻性研究纳入200例接受PFC Sigma膝关节假体及前参考系统植入的印度患者,随访至少2年。结果发现21%存在不同程度股骨切迹,但2年内无髁上骨折发生,切迹与活动范围或结局评分无关。
要点
- 200例中21%出现切迹:I级13%、II级6.5%、III级1%、IV级0.5%。
- 2年随访期内无髁上骨折发生。
- 切迹对活动范围及最终评分无影响。
核心结论
- 尽管切迹最好避免,但本研究显示全膝关节置换术后切迹与股骨髁上骨折无相关性。
- 切迹似乎对活动范围或最终结局评分无任何影响。
研究设计与样本
- 单中心前瞻性研究,所有接受全膝关节置换术的患者均被纳入并随访至少2年。
- 所有患者使用PFC Sigma膝关节假体(DePuy Synthes),并采用前参考系统进行植入。
- 采用膝关节协会评分进行结局评分,采用Gujarathi分级方案对切迹进行分级。
- 放射学结局由独立观察者评估,线性回归分析评估切迹对活动范围和最终评分的影响。
主要发现
- 200例中21%存在不同程度的切迹,I级占13%,II级占6.5%,III级占1%,IV级占0.5%。
- 2年内无髁上骨折发生。
- 切迹对活动范围或结局评分无影响。
关键数值与推荐
- 切迹分级采用Gujarathi分级方案:I级13%、II级6.5%、III级1%、IV级0.5%。
- 结局评分采用膝关节协会评分。
- 放射学评估由独立观察者完成。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Notching of the anterior femoral cortex during total knee arthroplasty (TKA) has been attributed to cause supracondylar fractures of the femur. Anatomic variations in the femur bone in different races make notching inevitable when standard designs of prostheses are used. The objective of this study is to determine the prevalence of notching when a PFC Sigma knee was used in an Indian population sample using the anterior referencing system and to assess the frequency of femoral shaft fractures in these cases. METHODS: This is a single-center, prospective study. All patients undergoing TKA were recruited and followed up for a minimum of 2 years. All patients had a PFC Sigma knee (DePuy Synthes), and the anterior referencing system was used for implantation. The Knee Society Score was used for outcome scoring and the Gujarathi's schema for the grading of notching. Radiological outcomes were evaluated by an independent observer. Linear regression analysis assessed the effect of notching on range of motion and final score. RESULTS: Of the 200 cases, 21% had varying degrees of notching. Grade I was seen in 13%, grade II in 6.5%, grade III in 1%, and grade IV in 0.5% in this series. There was no supracondylar fracture in 2 years. Notching had no bearing on the range of movement or outcome scores. CONCLUSION: Although notching is best avoided, this study has shown no correlation between notching and supracondylar fracture of the femur following TKA. It does not appear to have any bearing on the range of movement or final outcome scores.
引用
- Puranik HG, Mukartihal R, Patil SS, et al. Does Femoral Notching During Total Knee Arthroplasty Influence Periprosthetic Fracture. A Prospective Study. J Arthroplasty. 2019. PMID: 30904365. doi:10.1016/j.arth.2019.02.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。