DXA衍生三维测量对骨质疏松相关椎体骨折的判别:一项回顾性病例对照研究
该回顾性病例对照研究分析74例绝经后女性(37例发生椎体骨折,37例年龄匹配无骨折对照),评估腰椎DXA衍生三维测量与骨质疏松相关椎体骨折的关联。骨折组小梁体积骨密度较对照组低16.1%,判别骨折的AUC为0.733,优于面积骨密度的0.682。作者认为需分析大型队列以确定这些测量能否改善临床骨折风险预测。
要点
- 骨折组小梁体积骨密度较对照组低16.1%(p<0.001),为判别骨折的最佳指标。
- 小梁体积骨密度判别骨折的AUC为0.733,面积骨密度为0.682。
- L1椎体骨折亚组中小梁体积骨密度AUC最高为0.827,面积骨密度为0.758。
核心结论
- 本研究表明DXA衍生三维模型的皮质和小梁测量能判别骨折组与对照组。
- 作者认为需分析大型队列以确定这些测量能否改善临床实践中的骨折风险预测。
研究设计与样本
- 回顾性病例对照研究,分析74例绝经后女性数据库:37例发生椎体骨折,37例年龄匹配无任何类型骨折的对照。
- 基线时(骨折组为骨折事件前)采集腰椎DXA扫描并测量面积骨密度。
- 使用基于DXA的三维建模软件(3D-SHAPER)评估体积骨密度等DXA衍生三维测量,体积骨密度计算于小梁、皮质和整体骨,并测量皮质厚度和皮质表面骨密度。
主要发现
- 骨折组面积骨密度较对照组低9.3%(p<0.01)。
- 骨折组椎体小梁体积骨密度较对照组低16.1%(p<0.001)。
- 小梁体积骨密度判别骨折组与对照组的AUC为0.733,面积骨密度为0.682。
- 亚组分析中总体观察到相似结果;L1椎体骨折亚组小梁体积骨密度AUC最高为0.827,面积骨密度为0.758。
关键数值与推荐
- 骨折组面积骨密度较对照组低9.3%(p<0.01)。
- 骨折组椎体小梁体积骨密度较对照组低16.1%(p<0.001)。
- 小梁体积骨密度判别骨折的AUC为0.733,面积骨密度为0.682。
- L1椎体骨折亚组小梁体积骨密度AUC为0.827,面积骨密度为0.758。
临床怎么用
- 原文未据此给出推荐。
局限性
- 作者认为需分析大型队列以确定这些测量能否改善临床实践中的骨折风险预测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: A retrospective case-control study assessing the association of DXA-derived 3D measurements with osteoporosis-related vertebral fractures was performed. Trabecular volumetric bone mineral density was the measurement that best discriminates between fracture and control groups. INTRODUCTION: The aim of the present study was to evaluate the association of DXA-derived 3D measurements at the lumbar spine with osteoporosis-related vertebral fractures. METHODS: We retrospectively analyzed a database of 74 postmenopausal women: 37 subjects with incident vertebral fractures and 37 age-matched controls without any type of fracture. DXA scans at the lumbar spine were acquired at baseline (i.e., before the fracture event for subjects in the fracture group), and areal bone mineral density (aBMD) was measured. DXA-derived 3D measurements, such as volumetric BMD (vBMD), were assessed using a DXA-based 3D modeling software (3D-SHAPER). vBMD was computed at the trabecular, cortical, and integral bone. Cortical thickness and cortical surface BMD were also measured. Differences in DXA-derived measurements between fracture and control groups were evaluated using unpaired t test. Odds ratio (OR) and area under the receiver operating curve (AUC) were also computed. Subgroup analyses according to fractured vertebra were performed. RESULTS: aBMD of fracture group was 9.3% lower compared with control group (p < 0.01); a higher difference was found for trabecular vBMD in the vertebral body (- 16.1%, p < 0.001). Trabecular vBMD was the measurement that best discriminates between fracture and control groups, with an AUC of 0.733, against 0.682 for aBMD. Overall, similar findings were observed within the subgroup analyses. The L1 vertebral fractures subgroup had the highest AUC at trabecular vBMD (0.827), against aBMD (0.758). CONCLUSION: This study showed the ability of cortical and trabecular measurements from DXA-derived 3D models to discriminate between fracture and control groups. Large cohorts need to be analyzed to determine if these measurements could improve fracture risk prediction in clinical practice.
引用
- López Picazo M, Humbert L, Di Gregorio S, et al. Discrimination of osteoporosis-related vertebral fractures by DXA-derived 3D measurements: a retrospective case-control study. Osteoporos Int. 2019. PMID: 30770938. doi:10.1007/s00198-019-04894-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。