金属对金属铰链型膝关节翻修假体中期的血清金属离子水平是否值得关注
该研究分析了2013至2017年间接受金属对金属(MoM)铰链型膝关节翻修假体的患者,其中23例在中位28个月随访时检测血清铬和钴离子水平。结果显示铬中位数6.3 ppb、钴中位数10.5 ppb,16例患者离子水平升高,且离子水平与膝关节协会评分(KSS)呈中度相关。作者认为离子升高常见且值得关注,建议将血清离子分析纳入铰链型全膝关节置换术(TKA)术后常规随访。
要点
- MoM铰链型膝关节翻修假体术后中位28个月随访时,血清铬和钴离子水平中位数分别为6.3 ppb和10.5 ppb。
- 23例患者中16例血清离子水平升高(>5 ppb),且离子水平与KSS呈中度相关。
- 作者建议将血清离子分析作为任何铰链型TKA术后随访的常规部分。
核心结论
- 在该MoM铰链设计术后短期随访中,血清金属离子水平升高和放射透亮线常见,作者认为这一发现值得高度关注。
- 尽管尚无患者接受翻修,但这些患者将被密切监测。
- 作者推荐将血清离子分析作为任何铰链型TKA术后随访的常规部分,以更好地理解该现象的潜在后果。
研究设计与样本
- 回顾性分析2013至2017年间198例膝关节翻修术,其中32例(17.7%)使用最新一代MoM铰链型膝关节假体,另纳入3例使用相同设计的复杂初次TKA。
- 35例接受该假体的患者中,23例(占该假体总组的65%;11男12女)获得随访,中位随访28个月(范围13-61个月),其余12例(35%)失访。
- 手术时中位年龄68岁(范围52-84岁),所有纳入患者无其他MoM轴承植入物。
- 血清铬(III)和钴离子水平采用质谱法检测,离子水平>5 ppb视为升高;临床结果采用原始KSS评估。
- 证据等级为IV级,治疗性研究。
主要发现
- 血清铬中位水平为6.3 ppb(范围0.6-31.9 ppb),血清钴中位水平为10.5 ppb(范围1.0-47.5 ppb)。
- 23例患者中16例血清离子水平升高。
- KSS与铬水平呈中度相关(p=0.029,r=0.445),与钴水平呈中度相关(p=0.012,r=0.502)。
关键数值与推荐
- 血清离子水平>5 ppb定义为升高。
- 使用原始KSS评估临床结果。
临床怎么用
- 作者推荐将血清离子分析作为任何铰链型TKA术后随访的常规部分,以更好地理解该现象的潜在后果。
- 作者认为术后血清金属离子水平升高和放射透亮线常见且值得高度关注,尽管尚无患者接受翻修,这些患者将被密切监测。
局限性
- 35例接受该假体的患者中12例(35%)失访。
- 作者在更典型的2年最低随访前报告,原因是发现血清离子水平升高但临床意义不明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Elevated serum levels of chromium and cobalt ions in metal-on-metal (MoM) bearing surfaces is a well-known phenomenon in THA. However, few studies have addressed this issue in complex primary and revision knee arthroplasty using a MoM hinged mechanism, and no study, to our knowledge, has investigated knees with MoM hinges in patients without megaprostheses (tumor prostheses). QUESTIONS/PURPOSES: We analyzed a series of patients who received MoM hinged revision knee prostheses and asked: (1) What are the serum metal ion levels at short-term followup? (2) Is there any correlation between metal ion levels and the Knee Society Score (KSS) at this followup? METHODS: Between 2013 and 2017, we performed 198 revision knee arthroplasties, of which 32 (17.7%) were performed with a latest-generation MoM hinge knee design. In addition, three complex primary TKAs utilizing the same design were included in this study. The device features a metal-on-polyethylene bearing with a MoM hinge. During that period, our general indications for using a hinge were single-stage and two-stage revision surgeries, revisions with large bone defects, and primary TKA with > 20° mechanical malalignment or collateral ligament insufficiency. Of the 35 patients who received this device, 23 patients (65% of the overall group who received this implant; 11 males, 12 females) were available for followup at a median of 28 months (range, 13-61 months), and the remaining 12 (35%) patients were lost to followup. Our rationale for reporting before the more typical 2-year minimum was the finding of elevated serum ion levels with unclear clinical significance. Median age at the time of surgery was 68 years (range, 52-84 years). None of the patients included in the study had other implants with MoM bearings. Serum ion levels of chromium (III) and cobalt were assessed using mass spectrometry. Ion levels > 5 ppb were considered elevated. Clinical outcome was assessed using the original KSS. RESULTS: Median chromium serum level was 6.3 ppb (range, 0.6-31.9 ppb) and median cobalt serum level was 10.5 (range, 1.0-47.5 ppb). Of the 23 patients, 16 had elevated serum ion levels. There was a moderate correlation between KSS and both chromium (p = 0.029, r = 0.445) and cobalt (p = 0.012, r = 0.502) levels. CONCLUSIONS: Elevated metal ion levels and radiolucent lines are common after surgery with this MoM hinge design at short-term followup, and we believe this finding is of great concern. Although no patient has yet been revised, these patients will be closely monitored. We recommend that serum ion analysis become a routine part of followup after any hinge TKA in an attempt to better understand the potential consequences of this phenomenon. LEVEL OF EVIDENCE: Level IV, therapeutic study.
引用
- Klasan A, Meine E, Fuchs-Winkelmann S, et al. Are Serum Metal Ion Levels a Concern at Mid-term Followup of Revision Knee Arthroplasty With a Metal-on-metal Hinge Design? Clin Orthop Relat Res. 2019. PMID: 30811355. doi:10.1097/CORR.0000000000000638
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。