文献速递关节外科

外侧单髁膝关节置换术长期随访高生存率与极低磨损:平均随访17年的54例病例系列

High Survival Rate and Very Low Wear of Lateral Unicompartmental Arthroplasty at Long Term: A Case Series of 54 Cases at a Mean Follow-Up of 17 Years.
PubMed 文献 · J Arthroplasty · 2019-01-29

该病例系列纳入1988年1月至2003年10月间52例患者的54例外侧单髁膝关节置换术(UKA),均使用固定全聚乙烯胫骨平台与股骨表面置换假体。平均随访17.9年,15年累积生存率82.1%、20年79.4%,平均聚乙烯磨损0.061 mm/y,翻修主要原因为骨关节炎进展。

要点

  • 外侧UKA固定全聚乙烯平台15年累积生存率82.1%,20年79.4%。
  • 平均随访17.9年,平均聚乙烯磨损为0.061 mm/y,无因磨损翻修。
  • 翻修主要原因为骨关节炎进展(87.5%),其次为胫骨假体无菌性松动(12.5%)。

核心结论

  • 固定全聚乙烯胫骨平台与股骨表面置换假体的外侧UKA长期生存率高且聚乙烯磨损极低。

研究设计与样本

  • 病例系列,1988年1月至2003年10月共行54例外侧UKA(52例患者),均因孤立性外侧骨关节炎,平均手术年龄65.4±11岁,39例获随访(30例存活、9例15年后死亡),平均随访17.9年(范围15-23年)。

主要发现

  • 末次随访时39膝中8膝(20.5%)接受手术翻修,15年累积生存率82.1%、20年79.4%。
  • 翻修主要原因依次为骨关节炎进展(87.5%)和胫骨假体无菌性松动(12.5%)。
  • 平均随访17.9年时平均聚乙烯磨损为0.061 mm/y,存活假体无影像学松动,无因磨损翻修。
  • 平均功能性国际膝关节学会评分66.5±26.8,平均客观评分84.4±13.2分。
  • 未翻修人群中90.5%在末次随访时满意或非常满意。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Survivorship of lateral unicompartmental knee arthroplasty (UKA) has progressively improved. However, there are few studies describing long-term results, and no study reports on polyethylene (PE) wear in lateral unicompartmental arthroplasty. The aims of this study are to determine the survival rate of lateral UKA with a fixed, all-PE bearing, and the PE wear of the tibial implant at a minimum of 15 years follow-up. METHODS: From January 1988 to October 2003, we performed 54 lateral UKAs in 52 patients. All patients had isolated lateral osteoarthritis (OA). The mean age at the index procedure was 65.4 ± 11 years. Thirty-nine UKAs were available for follow-up (30 alive and 9 dead after 15 years). Twelve patients had died before 15 years and 3 patients were lost to follow-up. The mean follow-up was 17.9 years (range, 15-23 years). RESULTS: At the final follow-up, 8 knees of 39 (20.5%) had a surgical revision. The cumulative survival rate was 82.1% at 15 years and 79.4% at 20 years. The main reason of revision was progression of OA (87.5%), followed by aseptic loosening of the tibial component (12.5%). With a mean follow-up of 17.9 years, the mean PE wear was 0.061 mm/y. There was no radiographic loosening in the surviving implants and no revisions for wear. The mean functional International Knee Society score was 66.5 ± 26.8, with a mean objective score of 84.4 points ± 13.2. In the population without revision, 90.5% were satisfied or very satisfied at the latest follow-up. CONCLUSION: Lateral UKA with a fixed, all-PE tibial bearing and a femoral resurfacing implant presents a high survivorship at long term, with very low PE wear.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Deroche E, Batailler C, Lording T, et al. High Survival Rate and Very Low Wear of Lateral Unicompartmental Arthroplasty at Long Term: A Case Series of 54 Cases at a Mean Follow-Up of 17 Years. J Arthroplasty. 2019. PMID: 30777626. doi:10.1016/j.arth.2019.01.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。